Montigo L-Series DF Planning Manual page 7

Flush face fireplace
Table of Contents

Advertisement

 With the High style of sheathing, the enclosed nailing flange extension MUST be used and
COMBUSTIBLE MATERIAL MUST NOT EXTEND BELOW THE NAILING FLANGE EXTEN-
SION. (See Figure 1). This method, while perfectly acceptable, exposes about ten inches
of black metal trim above the glass door. Only part of this trim can be covered by the op-
tional Montigo surround. This is perhaps the least preffered method of sheathing because
it exposes the largest surface of black trim.
 Standard style
Framing
Wall Sheathing Detail
(Exploded Side View - Not to Scale)
 When using the Standard style (See Figure 2). the nailing flange extension is omitted and
ONLY NON-COMBUSTIBLE MATERIALS MAY BE BROUGHT TO THE CABINET NAILING
FLANGE. With the standard style, all of the black metal fireplace trim can be covered with
either of the optional Montigo surrounds.
'Standard'
Non-Combustible
Sheathing
Montigo flush face
Fireplace
Figure 2
Page 7