Amplifier Section Bias Adjustment; Standard Value; Cup11769Y (Bias Pcb) - Harman Kardon AVR335 Service Manual

7 x 55w 7.1 channel a/v receiver
Hide thumbs Also See for AVR335:
Table of Contents

Advertisement

AVR335

AMPLIFIER SECTION BIAS ADJUSTMENT

Measurement condition
. No input signal or volume position is minimum.

Standard value.

±
. Ideal current = 48mA (
. Ideal DC Voltage = 25.92mV (
CN81
VR87
DC VOLTMETER..............Connect to CN81,CN82,CN83,CN84,CN85,CN86,CN87
NO.
1
2
3
4
5
6
7
5%)
±
5%)

CUP11769Y (BIAS PCB)

......
CN82
VR86
Channel
Front Left
Front Right
Center
Surround Left
Surround Right
Surround Back Left
Surround Back Right
......
CN86
VR82
Adjust for
25.92mV (±5%)
25.92mV (±5%)
25.92mV (±5%)
25.92mV (±5%)
25.92mV (±5%)
25.92mV (±5%)
25.92mV (±5%)
24
harman/kardon
CN87
VR81
Adjustment
VR83
VR84
VR85
VR86
VR87
VR82
VR81

Hide quick links: