Haier HFU-09HA03/R(DB) Techical Data page 35

Domestic air conditioner dc inverter console type
Table of Contents

Advertisement

outdoor temp.
(humidity 46%)
DB/WB
-15℃
-10℃
-5℃
0℃
5℃
10℃
15℃
20℃
4000
3500
3000
2500
2000
1500
-15℃
HFU-09,12,18 HA03/R2(DB)
HFU-18HA03/R2(DB) performance curves
Heating discharge pressure.table
15℃
2300
2427
2536
2685
2784
2770
2670
3090
Heating discharge pressure
-10℃
-5℃
indoor temp.
20℃
2390
2611
2726
2940
3009
3040
2920
3321
0℃
5℃
Outdoor Temp
33
Performance Curves
25℃
2680
2810
3040
3131
3353
3475
3292
3550
10℃
15℃
Domestic Air Conditioner
15℃
20℃
25℃
20℃