Front Panel User Interface

The majority of the confi guration for the DXP is performed in the DCP. There a few things that can be changed using the DXP front panel, but the
primary purpose of the LCD and the Page and Set buttons is for status. The following is a breakdown of what you can do and see using the front panel
user interface. Press the PAGE button to move from page to page. Press the SET button to change to edit mode and to modify settings.
NOTE: The DXP ID must be set via the DXP front panel. This identifi es the DXP to the DCP. When creating the confi guration in DCP
Manager that includes this DXP, the same ID must be specifi ed on the DXP confi guration page (Aux/DXP tab in DCP Properties form). If
there is more than one DXP on the CobraNet network, each must have a unique ID.
Page
DXP State / Notes
1
Initial Boot
Connected and confi gured
2
Initial boot
Connected and confi gured
3
N/A
4
N/A
5
N/A
+48 VDC phantom power
6
N/A
7
8
N/A
9
N/A
10
Connected and confi gured
No Connection
11
— — indicates power supply
failure
TD-000371-00-A

LCD Display

QSC DXP
Status Only
QSC DXP n (1 or 2)
Press PAGE to move to next page.
Network name of connected DCP
ID:
Press SET cursor moves under fi rst digit of ID number
nn OFFLINE
Press SET to cycle numbers 0-9 for the fi rst digit
Press PAGE to move to second digit of ID number
ID:
Press SET to cycle numbers 0-9 for the second digit
nn ONLINE
Press Page cursor moves under Y of Save? Y:N
Press SET to save and restart the DXP, or
Press Page to move cursor to N
Press Set to exit edit mode without saving
Press PAGE to move to next page.
SN xxxxxxxxxx (Serial Number)
Status only
FW: 0.00.0000 (Firmware Version)
Press PAGE to move to next page.
Amp Power
Press SET cursor moves to ON
ON OFF
Press SET to turn the amps on.
Press PAGE to move the cursor to OFF
Press SET to put the amps in standby
Press PAGE to move to Exit
Press SET to exit edit mode
Press PAGE to move to next page, or press SET to start over.
MIC POWER
Press SET to toggle between ON and OFF
OFF (ON)
Press PAGE to move to next page.
MIC SENSITIVITY
Press SET to cycle through the choices:
27 dBu
27 dBu
21 dBu
10 dBu
-16 dBu
Press PAGE to move to next page.
AUTO. INPUTS
Status only
CC1=0 CC2=0
Press PAGE to move to next page.
Press SET to move cursor to Relay #1.
RELAY:
1
2
3
4
Press SET to toggle between O(pen) and C(lose)
O
O
C
C
Press PAGE to move to Relay #2.
Press SET to toggle between O(pen) and C(lose)
Continue in this manner. After setting Relay #4, Press PAGE to move to Ex.
Press SET to exit edit mode
Press PAGE to move to next page, or press SET to start over.
Contrast
Press SET to toggle through the choices. 1 is high contrast, 8 is low contrast.
1 - 8
Press PAGE to move to next page.
Status only
CobraNet
TX
RX
Press PAGE to move to next page.
OK
OK
— —
— —
Status only
POWER
A
B
Press PAGE to move to fi rst page.
OK
OK
— —
— —
Settings
6

Advertisement

Table of Contents
loading