Refrigerating Cycle; Condenser Assembly And Evaporator Assembly(Heat Exchange Assembly); Capillary Tube Assembly - Goldstar DH2510A Service Manual

Dehumidifier
Table of Contents

Advertisement

3.3 REFRIGERATING CYCLE

3.3.1 CONDENSER ASSEMBLY AND EVAPORATOR
ASSEMBLY(HEAT EXCHANGE ASSEMBLY)
1. Remove the motor mount. (Refer to 3.2.3)
2. Pierce the pinch-off tube to discharge the
refrigerant, using a FREON
3. Remove the insulation on the H/E assembly
4. After discharging the refrigerant completely,
remove 4 screws between the shroud and H/E
assembly. (See Figure 18)
5. Unbrace two interconnecting tubes of the
compressor.
6. Remove the H/E assembly from the shroud.
(See Figure 19)
7. Unbrace the interconnecting tube at the
connections of each condenser and evaporator
assembly.
8. Remove 4 screws between condenser and
evaporator assembly. (See Figure 20)

3.3.2 CAPILLARY TUBE ASSEMBLY

1. Remove the H/E assembly. (Refer to section 3.3.1)
2. After discharging the refrigerant completely,
unbrace the connecting pipes of capillary assembly
and pulling them outward. (See Figure 21)
recovery system.
TM
—13—
Figure 18
Figure 19
Figure 20
Figure 21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dh4010aDh5010a

Table of Contents