  • Page 2: Table Of Contents

    Standard Timer Operation ...9 Recipe Timer Operation ...11 View Recipe ...12 Programming Recipe Timer ...12 Unloading ...14 Wire Cage...14 Agitators and Attachments ...16 CLEANING ...17 MAINTENANCE ...18 Lubrication ...18 Adjustments ...19 TROUBLESHOOTING ... 20 Service...20 © HOBART 2006 TABLE OF CONTENTS...
  • Page 3: General

    Prior to installation, test the electrical service to assure that it agrees with the specifications on the machine data plate. Place the mixer on a suitable sturdy level surface. There should be adequate space around the mixer for the user to operate the controls and to install and remove bowls.
  • Page 4: Electrical Connections

    ELECTRICAL CODES. Check Initial Operation 1. Apply power to the mixer by inserting the cord plug into a properly grounded outlet. 2. Install the bowl and raise into mix position, with the bowl support up and bowl guard wire cage closed.
  • Page 5: Operation

    The Legacy mixer is equipped with SmartTimer OPERATION section for their functions. The bowl guard wire cage must be in closed position or the mixer will not operate. The bowl must remain in mix position on bowl support and the bowl support must be raised (mix position) or the mixer will not operate.
  • Page 6: Standard Controls

    Standard Controls Models HL120/HL200 (With Three Mix Speeds Plus Stir Speed) STOPS MIXER STARTS MIXER HL120/HL200 Mixer Speeds STIR (Slow) The lowest speed is for incorporating ingredients. SPEED 1 (Low) This speed is for heavy mixtures such as pizza dough, heavy batters and potatoes.
  • Page 7: Recipe Timer Control

    Operates exactly as the standard controls utilizing continuous and timed mixing. Recipe Mode Use mode buttons to switch mixer operation between recipe and standard timed operation. Up to 4 recipes can be stored in memory Each recipe can contain 5 steps Each step can be programmed to operate with the following speeds and time.
  • Page 8: Bowl Placement

    The bowl must be installed before the agitator is installed. To install the bowl, lower the bowl support and position bowl so the alignment pins on the left side of the bowl support fit in the holes in the bowl tab. (Fig. 3) Place the slotted tab on bowl into the lower part of the pin.
  • Page 9: Prepare For Mixing

    NOTE: If the wire cage is opened at any time, the mixing operation will stop. To resume the mixing operation, close the wire cage and press the START button. 4. Use the STOP button to stop the mixer; the mixing time is displayed in the TIME window.
  • Page 10 2. Press the START button to begin mixing; the timer starts counting down from the set time. a. To stop the mixer at any time, press the STOP button. To resume mixing, press the START button. For example: The mixer is started at SPEED 1 for 30 seconds and is stopped after 10 seconds.
  • Page 11: Recipe Timer Operation

    Recipe Timer Notes If pause is selected as a mix speed, the mixer START button must be pressed to advance to the next recipe step after the pause time has expired. If pause has been selected, the bowl guard can be opened and the time will continue to count down.
  • Page 12: View Recipe

    View Recipe When the mixer is in RECIPE mode, you can view the step settings of any recipe. Press the SELECT/SAVE button. Display will alternate between speed and time. The LED of the step being displayed will flash. Use the arrow buttons to view the next step.
  • Page 13 NOTES: If a value has been assigned for a step number, that LED will be lit. The LED for the selected step will blink. If the default value is still assigned to a step, the LED will not be lit. When programming, the Recipe and Time Selectors are disabled.
  • Page 14: Unloading

    Open the bowl guard wire cage: rotate it to your left (Fig. 9). Close the bowl guard wire cage: rotate it to your right until it stops, closed position (Fig. 10). NOTE: The bowl guard wire cage must be returned to the closed position for the mixer to operate. Fig. 9...
  • Page 15 Remove and Clean Bowl Guard Wire Cage (Fig. 11) 1. Rotate wire cage to your left until the three carriers align with the carrier escape slots in the circular ridge of the planetary drip cup. 2. Lift the wire cage straight up so the carriers escape from the slots on the drip cup. The bowl guard wire cage can now be removed by pulling toward you.
  • Page 16: Agitators And Attachments

    AGITATORS AND ATTACHMENTS Attachments for attachment hub and agitators are covered in a separate Hobart Legacy Mixer Use and Application Handbook on the Mixer Operator Information CD. Follow the instructions accordingly. Available Agitators and Attachments 12 & 20 Qt. B Flat Beater 12 &...
  • Page 17: Cleaning

    WARNING: UNPLUG MACHINE POWER CORD BEFORE BEGINNING ANY CLEANING PROCEDURES. The mixer should be thoroughly cleaned daily. DO NOT use a hose to clean the mixer; it should be washed with a clean, damp cloth. The base allows ample room for cleaning under the mixer.
  • Page 18: Maintenance

    WARNING: UNPLUG MACHINE POWER CORD BEFORE BEGINNING ANY MAINTENANCE PROCEDURES. Fig. 12 LUBRICATION Slideways The slideways (Fig. 12) should be lubricated approximately twice a year. To reach these areas, fully lower the bowl support and remove the apron, which is secured by slotted screws. Wipe a thin coat of Lubriplate 630AA on the bowl pad area of the bowl supports and on each slideway.
  • Page 19: Adjustments

    Measure Clearance Pour enough flour in the bowl to cover the bottom of the bowl where the beater travels. With the bowl fully raised (beater should not touch the bottom of the bowl), briefly run the mixer at the lowest speed.