Download Print this page

Mitsubishi Electric PKFY-P30NKMU-E2 Specifications page 2

Air conditioner
Hide thumbs Also See for PKFY-P30NKMU-E2:

Advertisement

PKFY-P30NKMU-E2 – DIMENSIONS
Model:
Left side
Knock out hole
for left piping
2-29/32(74)
A
1-3/16(30)
1-3/8(35)
2-19/32(66)
B
Sleeve
Through hole
(purchased locally)
2-15/16
2-15/16~ 3-5/32
( 75)
( 75~ 80)
Required space(Indoor unit)
Min.8-21/32(220)
Min.2-27/32(72.4)
4- 11/32( 9) Bolt hole
75- 3/16( 5.1)
Tapping
screw hole
5/8(15.5)
0
31/32(25)
1-31/32(50)
2-15/16(75)
3-15/16(100)
4-19/32(117)
4-29/32(125)
5-19/32(142)
7-9/16(192)
9-17/32(242)
11(279.5)
11-1/2(292)
Mitsubishi Electric Air Conditioning & Refrigeration Systems Wo rks acquired ISO
based on a review of quality warranties for the production of refrigeration and air
conditioning equipment.
ISO Authorization System
The ISO 9000 series is a plant authorization system relating to quality warranties as
development, production, installation and auxiliary services" for products built at
an authorized plant.
Mitsubishi Electric Air Conditioning & Refrigeration Systems Works acquired environmental
The ISO 14000 series is a set of standards applying to environmental protection set by the
International Standard Organization (ISO).
Top side
16-11/16(423.7)
17(431.7)
Front side
33-21/32(855)
46-1/16(1170)
Front side(Grille open)
Filter hook
17-15/32(444)Gas pipe
18-31/32(482)Liquid pipe
23-1/32(585)Drain hose
3
Under side
Vane(auto)
Louver(manual)
Knock out hole
for lower piping
(inch)
Air inlet
C
Air outlet
Min.2(50.5)
2-9/16(65)
Center measurement hole
3/32( 2.5)
Mount board
Knock out hole for
Wall hole for
Wall hole for
left rear piping
right rear piping
left rear piping
2-15/16×18-29/32(75×480)
Right side
Mount board
9-1/2(241)
3/16(5)
11-5/8(295)
Operation lamp
Knock out hole
for right piping
DEFROST/STAND BY lamp
Receiver
Terminal block for power supply
Terminal block for transmission
Terminal block for
MA-remote controller
Emergency operation switch
(cooling/heating)
2
4-27/32(123)
1
6-1/16(154)
5-9/32(134)
Piping connection department
Refrigerant pipe: 3/8 O.D( 9.52)
1 Liquid pipe
B
Flared connection: 3/8F
Refrigerant pipe: 5/8 O.D( 15.88)
2 Gas pipe
Flared connection: 5/8F
3 Drain hose
5/8( 16) I.D
Knock out hole for piping
B
A
3-1/32(77)
2-9/16(65)
3-7/16(87)
13/32(10.7)
Indoor unit outline
2-1/8(54)
1-1/4(32)
31/32(25)
1/2(12.5)
0
1/2(12.5)
1-15/32(37.5)
2-15/32(62.5)
3-7/16(87.5)
4-1/8(104.5)
5-3/32(129.5)
6-9/16(167)
8-17/32(217)
9-1/32(229.5)
10-13/32(264)
11-1/2(292)
12-5/32(308.5)
12-1/4(311)
Mitsubishi Electric Sales Canada Inc.
www.MitsubishiElectric.ca
Specifications are subject to change without notice.
SB_PKFY-P30NKMU-E2_201205
Unit : in(mm)
C