Outdoor Unit CM1972A
NOTE
• This performance chart shows operation of a single wall-mounted indoor unit. The performance chart will vary depending on
the indoor unit type.
• Check each performance value in test-run mode. Electrical performance values represent a combined indoor/outdoor value.
(In this case, be sure to stop all the indoor units where performance is not being checked.)
• The performance is for a tubing length of 24.6ft (7.5m). If the tubing length is different, the performance chart will vary.
Indoor Unit XMS1272
×
Cooling Characteristics
(RH : 46%, Indoor fan speed : High fan)
(230V, 60Hz)
(1) Low pressure performance chart
174
(1.2)
Lo fan
160
(1.1)
146
(1.0)
132
(0.9)
77
(25)
(2) Operating current performance chart
Lo fan
6
5
4
3
77
(25)
(3) Indoor discharge air performance chart
68.0(20)
Lo fan
64.4(18)
60.8(16)
57.2(14)
53.6(12)
50.0(10)
46.4( 8)
42.8( 6)
77
(25)
1
Hi fan
86
95
(30)
(35)
Outdoor air temperature °F (°C)
Hi fan
HH fan
86
95
(30)
(35)
Outdoor air temperature °F (°C)
Hi fan
HH fan
86
95
(30)
(35)
Outdoor air temperature °F (°C)
29
HH fan
104
(40)
104
(40)
104
(40)