Kidde PI9000 UK User Manual page 6

9 volt battery operated photoelectrick /ionization smoke alarm with "hush" control to temporarily silence nuisance alarms, and alarm memory
Table of Contents

Advertisement

1. Remove the mounting plate from the back of the alarm by hold-
ing the mounting plate and twisting the alarm in the direction
indicated by the "OFF" arrow on the alarm cover.
2. To insure aesthetic alignment of the alarm with the hallway or
wall, the "A" line on the mounting plate should be parallel with
the hallway when ceiling mounting or horizontal when wall
mounting.
3. After selecting the proper smoke alarm location as described in
section 1, attach the mounting plate to the ceiling as shown in
figure 4. For wall mounting see figure 4. Place mounting plate
on the wall. Be sure the "A" line is horizontal. Use the screws
and anchors provided to secure the mounting plate (use 3/16"
drill bit for anchor holes).
4.Battery installation instructions are provided on the inside of the
battery door.
To ensure proper installation of the smoke alarm battery, follow
the instructions.
5.When installing the battery, press the battery reminder finger
down into the battery compartment and install the battery (see
figure 5).
CAUTION! IF THE BATTERY REMINDER FINGER IS NOT HELD
DOWN IN THE BATTERY COMPARTMENT BY THE BATTERY,
THE BATTERY DOOR WILL NOT CLOSE AND THE UNIT WILL
NOT ATTACH TO THE MOUNTING BRACKET.
6.Install the alarm on the trim ring and rotate the alarm in the
direction of the "ON" arrow on the cover until the alarm ratch-
ets into place (this ratcheting function allows for aesthetic align-
ment).
Battery
Reminder
Finger
FIGURE 5