FALSE ALARM CONTROL
Model FADC230 features False Alarm Control that, when activated, quiets unwanted
alarms for up to 15 minutes.
To use the False Alarm Control:
Press and release the test button during an unwanted alarm. The alarm should
stop within ten seconds. This means the smoke alarm is in False Alarm Control.
If the smoke alarm does not go into False Alarm Control and continues to sound
its loud alarm horn, or if it initially goes into False Alarm Control then resounds the
alarm, the smoke is too heavy and could be a dangerous situation— take emer-
gency action.
TESTING THE SMOKE ALARM
!
W
A
R
N
I
N
G
Test each smoke alarm to be sure it is installed correctly and operating properly.
Test all smoke alarms in an interconnected system after installation.
The Push-to-Test button accurately tests all functions. DO NOT use an open
flame to test this smoke alarm. You may ignite and damage the smoke alarm or
your home.
Test smoke alarms weekly and upon returning from holiday or when no one has
been in the household for several days.
Stand at arm's length from the smoke alarm when testing. The alarm horn is
loud to alert you to an emergency and can be harmful to hearing.
Test all smoke alarms weekly by doing the following:
1. Check Push-to-Test button. A constant green light indicates the smoke alarm is
receiving 230V AC, 50Hz power. A red flashing LED about once a minute verifies
operation. The red flashing LED also verifies that a working battery is present.
2. Firmly depress the Push-to-Test button for at least five (5) seconds. The smoke
alarm will sound a loud beep about four (4) times a second. The alarm may
sound for up to 10 seconds after releasing the Push-to-Test button.
NOTE: If smoke alarms are interconnected, all smoke alarms should sound an
alarm within three seconds after any test button is pushed and the tested
smoke alarm sounds.
3. If smoke alarm does not sound, turn off power at main fuse box or circuit
breaker and check wiring. Retest smoke alarm.
!
DANGER: If alarm horn sounds, and smoke alarm is not being
tested, the smoke alarm is sensing smoke. THE
SOUND OF THE ALARM HORN REQUIRES YOUR
IMMEDIATE ATTENTION AND ACTION.
MAINTENANCE AND CLEANING
In addition to weekly testing, Model FADC230 also requires periodic battery
replacement. Regularly clean smoke alarm to remove dust, dirt, and debris.
!
WARNING: Alarm comes equipped with a dust cover, which
prevents dust and debris from damaging the unit
during construction or remodeling. Remove dust
cover before operation. Alarm will not operate
properly while covered.
!
DANGER:
ELECTRICAL SHOCK HAZARD. Turn off main power
at fuse box or consumer unit by removing fuse or
switching appropriate circuit breaker to OFF position
before replacing battery or cleaning smoke alarm.
BATTERY REPLACEMENT
!
CAUTION: Danger of explosion if battery is incorrectly replaced.
Always turn off power to smoke alarm before replacing battery. Replace battery at
least once a year or immediately when the low battery signal sounds once a minute,
even though the smoke alarm is receiving AC power.
Use only the following batteries as replacements in this smoke alarm:
Eveready 522 or 1222; Duracell MN 1604; or Ultralife U9VL-J
Replace only with the same or equivalent battery type recommended by the manu-
facturer. Discard used batteries safely according to manufacturer's instructions.
TEST THE ALARM FOR CORRECT OPERATION USING THE TEST BUTTON
WHENEVER THE BATTERY IS REPLACED.
!
WARNING: DO NOT USE ANY OTHER TYPE OF
BATTERY, EXCEPT AS SPECIFIED IN THIS MANUAL.
DO NOT USE RECHARGEABLE BATTERIES.
5
1. Turn off power to smoke alarm at main service
panel.
2. Slide battery door open as shown in the illustration.
3. Remove drained battery from compartment and
discard.
4. Install a fresh 9-volt battery.
5. Slide battery door closed.
6. Turn on power and test smoke alarm using
Push-to-Test button.
CLEANING
Clean the smoke alarm at least once a month to remove dust, dirt, or debris. Always
turn off power to smoke alarm before cleaning.
Using the soft brush or wand attachment to a vacuum cleaner, vacuum all sides
and cover of smoke alarm. Be sure all the vents are free of debris.
If necessary, turn off power and use a damp cloth to clean smoke alarm cover.
IMPORTANT: Do not attempt to remove the cover or clean inside the smoke alarm.
THIS WILL VOID YOUR GUARANTEE.
REPAIR
CAUTION: Do not attempt to repair this smoke alarm. Doing so will
!
void your guarantee.
If smoke alarm is not operating properly, see "Troubleshooting". If necessary and if
still under guarantee, return smoke alarm to Sensotec. Pack it in a well-padded
carton and send, postage prepaid to Sensotec address at the end of this manual.
If the smoke alarm is no longer under guarantee, have a licensed electrician
replace the smoke alarm immediately with a comparable Firex brand smoke alarm.
PRACTICE FIRE SAFETY
If the smoke alarm sounds its alarm horn, and you have not pushed the test
button, it is warning of a dangerous situation. Your immediate response is nec-
essary. To prepare for such occurrences, develop family escape plans, discuss
them with ALL household members, and practice them regularly.
Expose everyone to the sound of a smoke alarm and explain what the
sound means.
Determine TWO exits from each room and an escape route to the outside
from each exit.
Teach all household members to touch the door and use an alternate exit if
the door is hot. INSTRUCT THEM NOT TO OPEN THE DOOR IF THE
DOOR IS HOT.
Teach household members to crawl along the floor to stay below danger-
ous smoke, fumes, and gases.
Determine a safe meeting place for all members outside the building.
WHAT TO DO IN CASE OF A FIRE
1. Don't panic; stay calm.
2. Leave the building as quickly as possible. Touch doors to feel if they
are hot before opening them. Use an alternate exit if necessary. Crawl
along the floor, and DO NOT stop to collect anything.
3. Meet at a pre-arranged meeting place outside the building.
4. Call the fire brigade from OUTSIDE the building.
5. DO NOT GO BACK INSIDE A BURNING BUILDING. Wait for the fire
brigade to arrive.
These guidelines will assist you in the event of a fire. However, to reduce the
chance that fires will start, practice fire safety rules and prevent hazardous
situations.
6
TROUBLESHOOTING
!
DANGER:
Always turn off power at main fuse box or consumer
unit before taking trouble- shooting action.
!
WARNING:
DO NOT disconnect battery or mains power to
quiet an unwanted alarm. This will remove your
protection. You may also use the False Alarm
Control feature to quiet unwanted alarms.
PROBLEM
SOLUTION
Smoke alarm does not
1. Check that AC power
sound when tested.
is turned on. Green LED
should be illuminated.
NOTE: Push test but-
2. Turn off power. Remove
ton for at least five (5)
smoke alarm from
seconds while testin
g!
mounting plate and:
a. check that connector
plug is securely
attached.
b. check that battery is
properly attached to
connector.
3. Clean smoke alarm.
Smoke alarm sounds
1. Hire an electrician to
unwanted alarms when
move smoke alarm to a
residents are cooking,
new location. See
taking showers, etc.
"SMOKE ALARM
PLACEMENT"
Interconnected smoke
1. Press and hold test
alarms do not sound when
button for at least
system is tested.
three seconds after the
first unit sounds.
2. Hire an electrician to
ensure smoke alarms
are properly connected.
WARRANTY
Invensys Controls warrants to the original consumer purchaser each new
smoke alarm to be free from defects in material and workmanship under nor-
mal use and service for a period of six (6) years in the United Kingdom and
Republic of Ireland from date of purchase. Invensys Controls agrees to repair
or replace, at its option, any defective smoke alarm, provided that it is returned
with postage prepaid and with proof of purchase date to Invensys Controls.
This warranty does not cover damage resulting from accident, misuse or
abuse or lack of reasonable care of the product. This warranty is in lieu of all
other express warranties, obligations or liabilities. THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
LIMITED TO A PERIOD OF SIX (6) YEARS FROM PURCHASE DATE. Some
states do not allow limitations on how long an implied warranty lasts, so the
above limitations may not apply to you. IN NO CASE SHALL INVENSYS
CONTROLS BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAM-
AGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR
IMPLIED, WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY
ITS NEGLIGENCE OR FAULT. Some states do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you. This warranty gives you specific legal rights,
and you may also have other legal rights which vary from state to state.
Return units freight prepaid to your local reseller. For information on your local
reseller in the U.K. and Republic of Ireland, contact:
Sensotec Europe Ltd.
Unit 7, Bala Industrial Estate
Bala, Gwynedd LL23 7NL
United Kingdom
Tel.: +44 (0) 1678 520022
Fax.: +44 (0) 1678 520689
7
NOTES
191 E. North Avenue
Carol Stream, Illinois 60188
www.invensyscontrols.com
©2007 Invensys Controls
354-00004-001 Rev A 10/07
8

Advertisement

loading