3.2.2
Install the Power Cord completely through one of the channels at the top of either of the Panels
as shown below. A channel can be found in each of the four corners. Select the corner that will
be convenient in relation to site selection. For overhead power connection, do not insert the
cable through a channel but leave it free at the top.
If using cord set, it can only be routed through the channel closest to the Power Module (as
shown) and out of the bottom of the panel. The standard power cord is then plugged into the
Cord Set.
3.2.3
Place the styrofoam packing material on floor as shown and lay the Detection Unit on it with the
touchpad panel facing down. Use four (4) of the Screws and Finishing Washers to connect the
Detection Unit to Panels A and B. Do not tighten.
3.2.4
Open door of the Detection Unit and, first, connect Power Cord. Then, connect Cable A and
Cable B to the Panels as shown.
©2006 GARRETT METAL DETECTORS
MT 5500
User Manual
13
PN 1530200.F.0506