Free-standing epa certified wood-burning stoves country collection (22 pages)
Summary of Contents for Lennox Hearth Products LEGACY S260 T-TOP
Page 1
INSTALLATION AND OPERATION MANUAL Free-Standing EPA Certified Wood-Burning Stoves Save These Instructions For Future Reference P/N 775216M, Rev. F, 12/2011 Wood Stoves Model Legacy™ S260 T-Top A French manual is available upon request. Order P/N 775216CF. Ce manuel d’installation est disponible en francais, simplement en faire la demande. Numéro de la pièce 775216CF.
Stove Installation ................. 12 Pedestal Installation ..............13 Thank you for selecting a Lennox Hearth Products wood stove as the answer to your home supplemental heating needs. Post Installation Checks ............... 14 Brick Installation ................
13. Inspect your chimney at least once a month during the burn- IMPORTANT SAFETY AND WARNIING ing season to check for soot and creosote accumulations. INFORMATION Any accumulations over 1/8” thick should be removed by a professional chimney sweep. Do not attempt to burn out heavy creosote accumulations with a hot fire.
W.C. As per NFPA-211 standard (see paragraph below), the installer TESTING INFORMATION must take into account all variables within the installation and install the appliance in such a manner that satisfies the draft requirements of the appliance. See Chimney Guidelines below to assist you in selecting the This manual describes the installation and operation of these non-catalytic proper venting system for your installation.
(cat. no. H8159), available from all you need to clean to be safe. Be aware that the hotter the fire the Lennox Hearth Products dealers. less creosote is deposited, and weekly cleaning may be necessary...
Chimney and Connector CLEARANCES TO COMBUSTIBLES Minimum 6" or 8” diameter, minimum 24 MSG black steel connector WARNING: BE ABSOLUTELY SURE THE DISTANCE BETWEEN THE pipe with UL103HT listed factory-built chimney suitable for use with HEATER AND THE SURFACE OF ANY COMBUSTIBLE CONSTRUC- solid fuels or masonry chimney.
Page 7
INSTALLATION CLEARANCES - REFER TO FIGURES 2, 3 AND 4 PIPE INSTALLATION B (1) D (1) E† F (1,4) G (4) H (2) 6” Single Wall Residential 18” 15-1/2” 26” 16” 8” 11” 21” USA-37-1/4” (450mm) (394mm) (660mm) (406mm) 200mm (279mm) (533mm) CAN-1200mm...
Single Wall Pipe STAINLESS STEEL LINER Using 6”or 8” Diameter Single Wall Connector Pipe Using 6” or 8” Diameter Rigid Stainless Steel Liner INSTALL VENTING SYSTEM PER VENT MANUFACTURERS INSTALL VENTING SYSTEM PER VENT MANUFACTURERS INSTRUCTIONS! INSTRUCTIONS! Chimney Chimney Termination Termination Rain Cap Shown with Tubinox™ Stainless...
CHIMNEY INSTALLATION Double Wall Pipe • Install chimney as per manufacturer’s instructions. Some brands of Using 6” or 8” Diameter Type L-Vent Connector Pipe pipe may require removal of the spacer ring in the flue collar. Mobile (Manufactured) Home Installation Shown •...
Chimney Connector Systems and Clearances from Combustible System A Walls for Residential Heating Appliances (NFPA 211) Minimum chimney clearance to brick Refer to Figure 8 and combustibles 2 in. (51mm) System A. Minimum 3.5 in. (90 mm) thick brick masonry wall Minimum clearance 12 in.
If there is hidden damage, notify your 5. Do not over tighten the heatshield mounting bolts as it may bend the freight company or Lennox Hearth Products dealer immediately. heatshield. CAUTION: Wear gloves during installation in case of sharp edges on the stove.
14. All horizontal runs of pipe should be as short as possible and are STOVE INSTALLATION required by NFPA No. 211 to have an upward pitch or rise in the same direction the smoke travels of no less than 1/4” to the linear foot. The connector pipe must meet minimum clearances in any direction If not previously installed, install floor protection and move the to walls or other combustible materials.
5. If required, install the Outside Air Kit (cat. no. 71112) as per the PEDESTAL INSTALLATION following instructions. To locate the hole in the hearth for outside air mark and cut a 4” (102 mm) hole in the hearth. The hole’s center (For ash drawer pedestal see instructions included with pedestal) should be 3”...
FOR YOUR OWN PROTECTION AND INSURANCE PURPOSES, POST INSTALLATION CHECKS HAVE YOUR CHIMNEY AND CONNECTOR PIPE INSTALLATION INSPECTED BY YOUR LOCAL BUILDING CODE AUTHORITY OR 1. Check that all chimney pipe joints are securely fastened. FIRE MARSHAL BEFORE STARTING A FIRE IN YOUR STOVE. NOTIFY YOUR INSURANCE COMPANY.
WARNING: IF THE BRICKS ARE NOT INSTALLED EXACTLY AS BRICK INSTALLATION SHOWN, THEY COULD FALL OUT OF PLACE DURING RE- FUELING OR BURNING OF THE STOVE, CAUSING SERIOUS CAUTION: Wear gloves during brick installation in case of INJURY. sharp edges inside the stove. Note: Installation of the baffle boards and insulating blanket is easier Brick Sizes when you can still access the flue outlet (before connecting flue vent).
OPERATING HINTS STARTING AND MAINTAINING A FIRE Be sure to clean plated accessories with a household type glass 1. Burn only dry, well-seasoned wood for maximum heat output. In some cleaner and a very soft cloth to remove any fingerprints and states it is illegal to burn wet wood or anything other than clean, dry wood products.
BLOWER OPERATION Blower Operation The blower can be operated manually or automatically (blower will turn on when the stove is hot and turn off when the stove is cool). The rocker switch on the control panel allows you to select between manual operation or automatic operation as follows (see Figure 19): MANUAL OPERATION: Turn rocker switch to the “MANU- AL”...
OPERATING TECHNIqUES AND HINTS ACHIEVING CLEAN, LONG BURNS Recent developments in wood burning technology have made wood burning To achieve long burn times, after having thoroughly preheated the a cleaner and more convenient way to heat your home. Overall efficiency stove, let the stove top cool down to 275 to 400 degrees (on Elites, in a wood burning appliance is a combination of combustion efficiency locate thermometer on the face of the insert just above the door).
DOOR HINGES: If door hinges need lubricating, use an anti-seize com- to cleaning glass. A commercial glass cleaner pound (never use oil) available from your Lennox Hearth Products dealer. designed for stoves is recommended. Do not use DOOR LATCH: If your door latch fails to latch tightly and the gasket is abrasive cleaners.
TROUBLESHOOTING Problem Solution POOR DRAFT: Extend chimney in length or have the chimney realigned to the proper size flue. Oversized chimneys normally have poor drafts. Remember, the stoves’ draft depend solely on the natural draft of the chimney (See Draft Requirements on Page 4).
DO’S AND DON’TS DO NOT: Install or operate this stove before reading this manual. DO NOT: Close the draft beyond the point at which the flames are completely extinguished. DO NOT: Open the stove door without fully opening the draft first. DO NOT: Burn driftwood or wood that has been in salt water.
Page 22
Item # Cat. No Description H8062 FSB700 Blower Only Assembly w/ blower wiring Contact an Lennox Hearth Products dealer to obtain any of these harness parts. Never use substitute materials. Use of non-approved parts H5658 Fan Blade (FSB700) can result in poor performance and safety hazards.
Page 23
REPLACEMENT PARTS - MODEL S260 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 24
REPLACEMENT PARTS - MODEL S260 Door Parts Blower Parts NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 25
REPLACEMENT PARTS - MODEL S260 Leg and Leg Parts NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 26
REPLACEMENT PARTS - MODEL S260 Ash Drawer Pedestal and Pedestal NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
The Date On Which Your Appliance Was Installed __________________________ Your Dealer's Name _________________________________________________ Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.