Lennox Hearth Products LEGACY S260 T-TOP Installation And Operation Manual
Lennox Hearth Products LEGACY S260 T-TOP Installation And Operation Manual

Lennox Hearth Products LEGACY S260 T-TOP Installation And Operation Manual

Free-standing epa certified wood-burning stoves country collection

Advertisement

INSTALLATION AND OPERATION MANUAL
Free-Standing
EPA Certified
Wood-Burning Stoves
Save These Instructions
For Future Reference
P/N 775216M, Rev. F, 12/2011
A French manual is available upon request. Order P/N 775216CF.
Report # 050-S-02b-2
Ce manuel d'installation est disponible en francais, simplement en faire la demande. Numéro de
la pièce 775216CF.
This appliance must be properly installed and operated in order to prevent the
possibility of a house fire. Please read this entire installation and operation
manual before installing and using your wood stove. Failure to follow
these instructions could result in property damage, bodily injury or
Portland
US
Hot! Do not touch! The glass and surfaces of this appliance will
be hot during operation and will retain heat for a while after
shutting off the appliance. Severe burns may result.
Carefully supervise children in the same room as appliance.
Model Legacy™ S260 T-Top
even death. Contact your local building or fire officials to obtain
a permit and information on any installation requirements
and inspection requirements in your area.
WARNINGS
Wood Stoves

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products LEGACY S260 T-TOP

  • Page 1 INSTALLATION AND OPERATION MANUAL Free-Standing EPA Certified Wood-Burning Stoves Save These Instructions For Future Reference P/N 775216M, Rev. F, 12/2011 Wood Stoves Model Legacy™ S260 T-Top A French manual is available upon request. Order P/N 775216CF. Ce manuel d’installation est disponible en francais, simplement en faire la demande. Numéro de la pièce 775216CF.
  • Page 2: Table Of Contents

    Stove Installation ................. 12 Pedestal Installation ..............13 Thank you for selecting a Lennox Hearth Products wood stove as the answer to your home supplemental heating needs. Post Installation Checks ............... 14 Brick Installation ................
  • Page 3: Important Safety Information

    13. Inspect your chimney at least once a month during the burn- IMPORTANT SAFETY AND WARNIING ing season to check for soot and creosote accumulations. INFORMATION Any accumulations over 1/8” thick should be removed by a professional chimney sweep. Do not attempt to burn out heavy creosote accumulations with a hot fire.
  • Page 4: Testing Information

    W.C. As per NFPA-211 standard (see paragraph below), the installer TESTING INFORMATION must take into account all variables within the installation and install the appliance in such a manner that satisfies the draft requirements of the appliance. See Chimney Guidelines below to assist you in selecting the This manual describes the installation and operation of these non-catalytic proper venting system for your installation.
  • Page 5: Negative Pressure Warning

    (cat. no. H8159), available from all you need to clean to be safe. Be aware that the hotter the fire the Lennox Hearth Products dealers. less creosote is deposited, and weekly cleaning may be necessary...
  • Page 6: Clearances To Combustibles

    Chimney and Connector CLEARANCES TO COMBUSTIBLES Minimum 6" or 8” diameter, minimum 24 MSG black steel connector WARNING: BE ABSOLUTELY SURE THE DISTANCE BETWEEN THE pipe with UL103HT listed factory-built chimney suitable for use with HEATER AND THE SURFACE OF ANY COMBUSTIBLE CONSTRUC- solid fuels or masonry chimney.
  • Page 7 INSTALLATION CLEARANCES - REFER TO FIGURES 2, 3 AND 4 PIPE INSTALLATION B (1) D (1) E† F (1,4) G (4) H (2) 6” Single Wall Residential 18” 15-1/2” 26” 16” 8” 11” 21” USA-37-1/4” (450mm) (394mm) (660mm) (406mm) 200mm (279mm) (533mm) CAN-1200mm...
  • Page 8: Typical Installation Figures

    Single Wall Pipe STAINLESS STEEL LINER Using 6”or 8” Diameter Single Wall Connector Pipe Using 6” or 8” Diameter Rigid Stainless Steel Liner INSTALL VENTING SYSTEM PER VENT MANUFACTURERS INSTALL VENTING SYSTEM PER VENT MANUFACTURERS INSTRUCTIONS! INSTRUCTIONS! Chimney Chimney Termination Termination Rain Cap Shown with Tubinox™ Stainless...
  • Page 9: Chimney Installation

    CHIMNEY INSTALLATION Double Wall Pipe • Install chimney as per manufacturer’s instructions. Some brands of Using 6” or 8” Diameter Type L-Vent Connector Pipe pipe may require removal of the spacer ring in the flue collar. Mobile (Manufactured) Home Installation Shown •...
  • Page 10: Chimney - Wall Pass-Through Requirements

    Chimney Connector Systems and Clearances from Combustible System A Walls for Residential Heating Appliances (NFPA 211) Minimum chimney clearance to brick Refer to Figure 8 and combustibles 2 in. (51mm) System A. Minimum 3.5 in. (90 mm) thick brick masonry wall Minimum clearance 12 in.
  • Page 11: Leg And Heatshield Installation

    If there is hidden damage, notify your 5. Do not over tighten the heatshield mounting bolts as it may bend the freight company or Lennox Hearth Products dealer immediately. heatshield. CAUTION: Wear gloves during installation in case of sharp edges on the stove.
  • Page 12: Stove Installation

    14. All horizontal runs of pipe should be as short as possible and are STOVE INSTALLATION required by NFPA No. 211 to have an upward pitch or rise in the same direction the smoke travels of no less than 1/4” to the linear foot. The connector pipe must meet minimum clearances in any direction If not previously installed, install floor protection and move the to walls or other combustible materials.
  • Page 13: Pedestal Installation

    5. If required, install the Outside Air Kit (cat. no. 71112) as per the PEDESTAL INSTALLATION following instructions. To locate the hole in the hearth for outside air mark and cut a 4” (102 mm) hole in the hearth. The hole’s center (For ash drawer pedestal see instructions included with pedestal) should be 3”...
  • Page 14: Post Installation Checks

    FOR YOUR OWN PROTECTION AND INSURANCE PURPOSES, POST INSTALLATION CHECKS HAVE YOUR CHIMNEY AND CONNECTOR PIPE INSTALLATION INSPECTED BY YOUR LOCAL BUILDING CODE AUTHORITY OR 1. Check that all chimney pipe joints are securely fastened. FIRE MARSHAL BEFORE STARTING A FIRE IN YOUR STOVE. NOTIFY YOUR INSURANCE COMPANY.
  • Page 15: Brick Installation

    WARNING: IF THE BRICKS ARE NOT INSTALLED EXACTLY AS BRICK INSTALLATION SHOWN, THEY COULD FALL OUT OF PLACE DURING RE- FUELING OR BURNING OF THE STOVE, CAUSING SERIOUS CAUTION: Wear gloves during brick installation in case of INJURY. sharp edges inside the stove. Note: Installation of the baffle boards and insulating blanket is easier Brick Sizes when you can still access the flue outlet (before connecting flue vent).
  • Page 16: Operating Hints

    OPERATING HINTS STARTING AND MAINTAINING A FIRE Be sure to clean plated accessories with a household type glass 1. Burn only dry, well-seasoned wood for maximum heat output. In some cleaner and a very soft cloth to remove any fingerprints and states it is illegal to burn wet wood or anything other than clean, dry wood products.
  • Page 17: Blower Operation (Optional Kit)

    BLOWER OPERATION Blower Operation The blower can be operated manually or automatically (blower will turn on when the stove is hot and turn off when the stove is cool). The rocker switch on the control panel allows you to select between manual operation or automatic operation as follows (see Figure 19): MANUAL OPERATION: Turn rocker switch to the “MANU- AL”...
  • Page 18: Operating Techniques And Hints

    OPERATING TECHNIqUES AND HINTS ACHIEVING CLEAN, LONG BURNS Recent developments in wood burning technology have made wood burning To achieve long burn times, after having thoroughly preheated the a cleaner and more convenient way to heat your home. Overall efficiency stove, let the stove top cool down to 275 to 400 degrees (on Elites, in a wood burning appliance is a combination of combustion efficiency locate thermometer on the face of the insert just above the door).
  • Page 19: Maintenance

    DOOR HINGES: If door hinges need lubricating, use an anti-seize com- to cleaning glass. A commercial glass cleaner pound (never use oil) available from your Lennox Hearth Products dealer. designed for stoves is recommended. Do not use DOOR LATCH: If your door latch fails to latch tightly and the gasket is abrasive cleaners.
  • Page 20: Troubleshooting

    TROUBLESHOOTING Problem Solution POOR DRAFT: Extend chimney in length or have the chimney realigned to the proper size flue. Oversized chimneys normally have poor drafts. Remember, the stoves’ draft depend solely on the natural draft of the chimney (See Draft Requirements on Page 4).
  • Page 21: Do's And Don'ts

    DO’S AND DON’TS DO NOT: Install or operate this stove before reading this manual. DO NOT: Close the draft beyond the point at which the flames are completely extinguished. DO NOT: Open the stove door without fully opening the draft first. DO NOT: Burn driftwood or wood that has been in salt water.
  • Page 22 Item # Cat. No Description H8062 FSB700 Blower Only Assembly w/ blower wiring Contact an Lennox Hearth Products dealer to obtain any of these harness parts. Never use substitute materials. Use of non-approved parts H5658 Fan Blade (FSB700) can result in poor performance and safety hazards.
  • Page 23 REPLACEMENT PARTS - MODEL S260 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 24 REPLACEMENT PARTS - MODEL S260 Door Parts Blower Parts NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 25 REPLACEMENT PARTS - MODEL S260 Leg and Leg Parts NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 26 REPLACEMENT PARTS - MODEL S260 Ash Drawer Pedestal and Pedestal NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 27: Accessories

    ACCESSORIES - MODEL S260 Security Chimneys™ Pipe - 6” Diameter Product Reference Information Cat. No. Description Ship. Ship. Tubinox Components Weight Volume 6” Rigid Stainless Steel Liner H7887 SS260T-B, Stove / T Top / Traditional 450 lb. 19.5 cu. ft. Black Door / Nickel Nameplate Cat.
  • Page 28 ACCESSORIES - MODEL S260 Secure Temp® Factory-Built Chimney Secure Black™ Single Wall Stove Pipe 6” Secure Temp ASHT and Secure Temp G-ASHT 6” SW Pipe and Accessories Cat. No. Model Description Pc. / Container Cat. No. Model Description Pc. / Container Lengths and Fittings 6SWL6 6SWL6...
  • Page 29 Security Chimneys™ Pipe - 8” Diameter ACCESSORIES - MODEL S260 Cat. No. Model Description Pc. / Container Tubinox Components 8” Rigid Stainless Steel Liner Supports (continued) Cat. No. Model Description Pc. / Container TEE SUPPORT 8LL6 8LL6 LENGTH 8” X 6” 6SMA 6SMA GALVALUME ADJUSTABLE TEE...
  • Page 30 Secure Temp® Factory-Built Chimney ACCESSORIES - MODEL S260 8” Secure Temp ASHT and Secure Temp G-ASHT Cat. No. Model Description Pc. / Container Secure Black™ Single Wall Stove Pipe 8” SW Pipe and Accessories Lengths and Fittings Cat. No. Model Description Pc.
  • Page 31: Accessories

    ACCESSORIES - MODEL S260 Cat. No. Model Description Pc. / Container Supports (continued) WALL SUPPORT, ASHT+ 8” 8SMA 8SMA GALVALUME ADJUSTABLE TEE SUPPORT W/COUPLER OFFSET SUPPORT / WALL SUP- PORT ROOF SUPPORT FLOOR SUPPORT ANCHOR PLATE Braces and Firestops FIRESTOP 8RSM30 8RSM30 ANGLED FIRESTOP - 30 DEGREE...
  • Page 32: Safety / Listing Labels

    SAFETY / LISTING LABEL - ENGLISH 2011 2012 2013 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 33: Safety / Listing Labels

    SAFETY / LISTING LABEL - FRENCH NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 34: Replacement Parts Lists

    The Date On Which Your Appliance Was Installed __________________________ Your Dealer's Name _________________________________________________ Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

Table of Contents