11. Modification of Heater for High Altitude:
The Jandy Lite 2 model LJ heater is normally
shipped from the factory in the low altitude (sea
level) operational configuration. When requested,
the heaters can be configured and shipped for
higher altitudes. For field conversions to change
altitude configurations, manifold kits for mid
altitudes and high altitudes are available from
your Jandy pool products dealer or by contacting
the Customer Service Department at (707) 776-
8200 extension 245. See Section 11, "Parts List",
of this manual for the correct kit number for the
manifold assembly needed for your altitude.
Table 1 defines the altitude designations as
described by the "Standard for Gas Fired Pool
Heaters", ANSI Z21.56 in the United States and
"Gas Fired Appliances For Use At High Alti-
tudes", CAN 1-2.17 in Canada.
Table 1. Altitude Designations for the LJ Pool Heater
NATURAL GAS
ALTITUDE
UNITED
DESIGNATION
STATES
LOW ALTITUDE
0-3000 FT
MID ALTITUDE
3001-6000 FT
(H)
HIGH ALTITUDE
6001-10,000 FT NOT
(J)
LOW ALTITUDE
0-5000 FT
HIGH ALTITUDE
5001-10,000 FT NOT
(H)

1.7.2 Dimensions

See Figure 1 for a diagram showing the heater's
exterior dimensions and dimensions to critical connec-
tions on the heater.
SECTION 2.
Installation Instructions
WARNING
Improper installation or maintenance can cause
nausea or asphyxiation from carbon monoxide
in flue gases which could result in severe injury,
or death. For indoor installations, as an
additional measure of safety, Jandy Pool
Products, Inc. strongly recommends installation
of suitable Carbon Monoxide detectors in the
vicinity of this appliance and in any adjacent
occupied spaces.
CANADA
0-2000 FT
(0-610 m)
2001-4500 FT
(611-1370 m)
APPLICABLE
LP
0-4500 FT
(0-1370 m)
APPLICABLE
AVERTISSEMENT
Une installation ou un entretien inadéquat peut
causer la nausée ou l'asphyxie en raison du
monoxyde de carbone présent dans les gaz de
combustion et même entraîner des blessures
graves ou la mort. Pour les installations
intérieures, comme mesure de sécurité
additionnelle, Jandy Pool Products, Inc.
recommande fortement l'installation de
détecteurs de monoxyde de carbone près de
cet appareil ainsi que dans les espaces
adjacents occupés.

2.1 Introduction

Install the Lite2 heaters, vent caps and draft
hoods in accordance with the procedures in this
manual, local codes and ordinances, and in accor-
dance with the latest edition of the appropriate na-
tional code (see Section 1.4 "Codes and Standards").
All gas-fired products require correct installation
to assure safe operation. The requirements for pool
heaters include the following:
1.
Field assembly (if required)
2.
Appropriate site location (clearances) and
flooring
3.
Sufficient combustion and ventilation air
4.
Properly sized gas meter and piping
5.
Proper electrical wiring (if required)
6.
Adequate water flow
This manual provides the information needed to
meet these requirements. Review all application and
installation procedures completely before continuing
the installation.

2.2 Field Assembly

The Lite2 heater is shipped from the factory
with the top assembly in the low-profile configuration
for outdoor installation. The Lite2 heater is design
certified for indoor installation when equipped with a
draft hood, which must be installed without modifica-
tion.
The Lite2 heater is also certified for installation
in an outdoor shelter in Canada when equipped with a
draft hood. An outdoor shelter is an enclosure not
normally occupied which does not communicate
directly with occupied areas.
Check the rating plate on the heater or the Parts
List (Section 11) of this manual for the correct Jandy
draft hood or vent cap part number. See instructions
supplied with the draft hood or vent cap for installation
and attachment. When the draft hood is used, locate
the heater so as to be in the same atmospheric
pressure zone as the combustion air inlet to the heater.