B. Clearances
WARNING! Risk of Fire! You must comply with all minimum air space clearances to combustibles as specifi ed in Fig-
ure 6.2. DO NOT pack required air spaces with insulation or other materials.
Storm Collar
Roof Flashing
Shaded areas
represent
2 in. (51 mm) min.
air space clearance
required around pipe
(attic)
Attic
Insulation
Shield
(insulation)
(ceiling)
Offset/Return (secured
2 in. (51 mm) min.
with hanger straps)
(ceiling)
Must have 2 in. (51 mm)
Ceiling Firestop
minimum clearance
to header
0 in. to level
of standoffs
1/2 in. (13 mm) to back &
sides of appliance
48 in.
1219 mm
0 in.
to floor
Figure 6.2
Clearances to Combustible Materials
Note: Chimney air kit is not shown, but is required in Canada.
Heatilator • ST36D • 20396 • Rev AA • 11/08