Quadra-Fire Direct Vent Room Heater 839-1390 Owner's Manual page 35

Direct vent room heater
Table of Contents

Advertisement

Use two screws to connect the snap disc bracket
Figure 8.24
to the blower mounting bracket.
Route the wires from the snap disc to the right, upper edge
of the blower.
Insert the rheostat control into its opening from
Figure 8.25
beneath the control panel. Fit the rheostat nut on top and
tighten the nut using an 11/16 in. wrench. Attach the black
knob.
Gather any excess in the wiring and zip-tie to the switch
wires and piezo wire at the rear of the appliance.
NOTE: This blower utilizes a snap disc to control ON and
OFF operation. When the correct temperature is reached,
the blower will automatically turn ON. Use the rheostat knob
to adjust the fan to High or Low to suit your preferences.
September 1, 2008
Quadra-Fire · Sapphire · 250-7233H
Page 35