Download Print this page

Omega Engineering HH804W Specifications

Wireless dual input rtd, digital thermometer

Advertisement

Quick Links

HH804W
HH804WE
WIRELESS DUAL INPUT RTD
DIGITAL THERMOMETER
M4552/0711
INSTRUCTION
Shop online at: omega.com e-mail: info@omega.com
SHEET
For latest product manuals: omegamanual.info
MADE IN TAIWAN
OMEGAnet On-Line Service
®
Internet e-mail
omega.com
info@omega.com
Servicing North America:
U.S.A:
One Omega Drive, Box 4047
Stamford, CT 06907-0047
ISO 9001
Tel: (203) 359-1660
FAX: (203) 359-7700
Certified
e-mail: info@omega.com
Canada:
976 Bergar
Laval (Quebec) H7L 5A1, Canada
Tel: (514) 856-6928
FAX: (514) 856-6886
e-mail: info@omega.ca
For immediate technical or application assistance:
U.S.A
Sales Service: 1-800-826-6342/1-800-TC-OMEGA
and
Customer Service: 1-800-622-2378/1-800-622-BEST
Canada:
Mexico:
En Espan ol: (001) 203-359-7803
e-mail: espanol@omega.com
FAX: (001) 203-359-7807 info@omega.com.mx
Servicing Europe:
Benelux:
Postbus 8034, 1180 LA Amstelveen, The Netherlands
Tel: +31 (0)20 3472121
FAX: +31 (0)20 6434643
Toll Free in Benelux: 0800 0993344
e-mail: sales@omegaeng.nl
Czech
Frystatska 184, 733 01 Karviná, Czech Republic
Republic:
Tel: +420 (0)59 6311899
FAX: +420 (0)59 6311114
Toll Free: 0800-1-66342
e-mail: info@omegashop.cz
France:
11, rue Jacques Cartier, 78280 Guyancourt, France
Tel: +33 (0)1 61 37 2900
FAX: +33 (0)1 30 57 5427
Toll Free in France: 0800 466 342
e-mail: sales@omega.fr
Germany/ Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
Austria:
Tel: + 49 (0)7056 9398-0
FAX: +49 (0)7056 9398-29
Toll Free in Germany: 0800 639 7678
e-mail: info@omega.de
United
One Omega Drive, River Bend Technology Centre
Kingdom: Northbank, Irlam, Manchester
ISO 9002
M44 5BD United Kingdom
Certified
Tel: +44 (0)161 777 6611
FAX: +44 (0)161 777 6622
Toll Free in United Kingdom: 0800-488-488
e-mail: sales@omega.co.uk
It is the policy of OMEGA Engineering, Inc. to comply with all
worldwide safety and EMC/EMI regulations that apply. OMEGA
is constantly pursuing certification of its products to the
European New Approach Directives. OMEGA will add the CE
mark to every appropriate device upon certification.
The information contained in this document is believed to be
correct, but OMEGA accepts no liability for any errors it
contains, and reserves the right to alter specifications without
notice.
These products are not designed for use in, and
should not be used for, human applications.
INTRODUCTION
This instrument is a 4½ digit, compact-sized portable
digital thermometer designed to use external 100Ω Plati-
num RTD as temperature sensor. Temperature indication
follows Reference Temperature/Resistance Tables (Pt385
for European Curve, Alpha=.00385. Pt3926 for American
Curve, Alpha=.003926. Pt3916 for Japan Curve, Al-
pha=.003916.)

SAFETY INFORMATION

It is recommended that you read the safety and opera-
tion instructions before using the thermometer.
WARNING
To avoid electrical shock, do not use this instrument
when working voltages at the measurement surface
®
®
over 24V AC or DC.
WARNING
To avoid damage or burns, do not make temperature
measurement in microwave ovens.
FEDERAL COMMUNICATIONS
COMMISSION
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two condi-
tions:(1) this device may not cause harmful interfer-
ence, and (2) this device must accept any interference
received, including interference that may cause unde-
sired operation.
NOTE
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection. This equipment gener-
ates, uses and can radiated radio frequency energy and,
if not installed and used in accordance with the in-
structions, may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation If
this equipment does cause harmful interference to ra-
dio or television reception, which can be determined
by turning the equipment off and on, the user is en-
couraged to try to correct the interference by one or
more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and
receiver.
- Connect the equipment into an outlet on a circuit dif-
ferent from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV tech-
nician for help.
Shielded interface cables must be used in order to
comply with emission limits.
Changes or modifications not expressly approved by
the party responsible for compliance could void the
user's authority to operate the equipment.
WIRELESS NOTE
Wireless receiver must keep a distance at least 40cm
from the meter and meter to meter distance
must be at least 30cm.

Advertisement

loading

Summary of Contents for Omega Engineering HH804W

  • Page 1: Safety Information

    INTRODUCTION FEDERAL COMMUNICATIONS This instrument is a 4½ digit, compact-sized portable COMMISSION HH804W digital thermometer designed to use external 100Ω Plati- OMEGAnet On-Line Service ® Internet e-mail This device complies with Part 15 of the FCC Rules. omega.com info@omega.com num RTD as temperature sensor. Temperature indication...
  • Page 2 LCD’s main display will show channel number, Wireless Features: value). = = = =.= is displayed on the main display. the second display will show ID number. Frequency range: 910~920MHz (HH804W) The relative value is entered via overlay numbers, 5. TYPE(Pt385/Pt3926/Pt3916) Input RTD 868.1~868.5MHz (HH804WE) press overlay “ENTER”...
  • Page 3: Operator Maintenance

    RTD PROBE CONNECTION WARRANTY/DISCLAIMER Where Do I Find Everything I Need for OMEGA ENGINEERING, INC. warrants this unit to be free of defects in Process Measurement and Control? materials and workmanship for a period of 13 months from date of P/N: 14061-0800-9 MINI DIN PLUG purchase.

This manual is also suitable for:

Hh804weHh804we