Lennox Hearth Products ELITE E36ODGNE Installation Instructions Manual
Lennox Hearth Products ELITE E36ODGNE Installation Instructions Manual

Lennox Hearth Products ELITE E36ODGNE Installation Instructions Manual

Elite series outdoor gas fireplace

Advertisement

this appliance is only for use with the type of gas
indicated on the rating plate. this appliance is
not convertible for use with other gases, unless a
certified kit is used.
INStALLEr: Leave this manual with the appliance.
CONSuMEr: retain this manual for future reference.
INStALLAtEur: Laissez cette notice avec l'appareil.
CONSOMMAtEur: Conservez cette notice pour consula-
tion ultérieure.
WArNING: IF tHE INFOrMAtION IN tHIS MANuAL
IS NOt FOLLOWEd ExACtLy, A FIrE Or ExPLO-
SION MAy rESuLt CAuSING PrOPErty dAM-
AGE, PErSONAL INjury Or LOSS OF LIFE.
do not store or use gasoline or other flammable
vapors or liquids in the vicinity of this or any
other appliance.
What to do if you smell gas:
• dO NOt light any appliance.
• dO NOt touch any electrical switches, do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow your gas suppliers
instructions.
• If your gas supplier cannot be reached, call
the fire department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Portland
US
OtL report No. 6-F-4-5
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
INStALLAtION
INStruCtIONS
OUTDOOR GAS FIREPLACE
ELITE
OutdOOr GAS FIrEPLACE
P/N 850,034M rEV. d 04/2009
MODELS
E36OdGNE
E36OdGNE-H
E36OdGPE
E36OdGPE-H
A French manual is available upon request. Order Form Number
850,034CF.
Ce manuel d'installation est disponible en francais, simplement en
faire la demande. Numéro de la pièce 850,034CF.
AVErtISSEMENt: ASSurEz-VOuS dE BIEN SuIVrE
LES INStruCtIONS dONNÉES dANS CEttE NOtICE
POur rÉduIrE Au MINIMuM LE rISQuE d'INCENdIE
d'ExPLOSION Ou POur ÉVItEr tOut dOMMAGE MA-
tÉrIEL, tOutE BLESSurE Ou LA MOrt.
Ne pas entreposer ni utiliser d'essence ni d'autre
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
QuE FAIrE SI VOuS SENtEz uNE OdEur dE GAz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bátiment où
vous vous trouvez.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournis-
seur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incendies.
L'installation et l'entretien doivent être assurés par
un installeur ou un service d'entretien qualifié ou par
le fournisseur de gaz.
SERIES
®
E42OdGNE
E42OdGNE-H
E42OdGPE
E42OdGPE-H


Advertisement

Table of Contents
loading

Summary of Contents for Lennox Hearth Products ELITE E36ODGNE

  • Page 1 P/N 850,034M rEV. d 04/2009 this appliance is only for use with the type of gas indicated on the rating plate. this appliance is MODELS not convertible for use with other gases, unless a certified kit is used. E36OdGNE E42OdGNE E36OdGNE-H E42OdGNE-H E36OdGPE E42OdGPE INStALLEr: Leave this manual with the appliance.
  • Page 2: Table Of Contents

    tABLE OF CONtENtS 2 - one envelope containing the literature pack- Electronic appliances are designed to oper- age which consists of the Homeowner's ate on natural gas or propane. An electronic intermittent pilot ignition system provides safe, manual, Installation Instructions and War- Packaging .........page efficient operation.
  • Page 3: Requirements

    NEW yOrK ANd MASSACHuSEttS Gas Pressure - All Models Orifice Sizes - Sea Level to High Altitude (All Models) rEQuIrEMENtS Tables 2 and 3 show the appliances' inlet and manifold gas pressure. These appliances are tested and approved for These appliances may be installed in the installation at elevations of 0-4500 feet (0-1372 following USA locations with the following meters) above sea level, using the standard...
  • Page 4: Location

    ASSEMBLy OutLINE ASSEMBLy StEPS When locating the fireplace, consideration must be given to combustibles and final finishing. Before you Start See Figure 18 and confine the final location Note: The following steps represent the normal of combustible finish materials to the "Safe sequence of installation.
  • Page 5 When Planning for the installation of the fire- place, the framing height must be increased from 46-/2 inches to 47-/4 inches, when installing the drain pan. An additional space below the fireplace will also be required to threaded plumb a drain line. threaded reducer Elbow 3/4...
  • Page 6: Clearance Specifications

    CLEArANCE SPECIFICAtIONS (See Note 2) J or K = FIREPLACE OPENING = AIR SUPPLY INLET = AREA WHERE FIREPLACE IS NOT PERMITTED 2 in..clearances above grade, 3 ft. (USA) ..clearance to service regulator veranda, porch, deck or 6 ft.
  • Page 7: Fireplace Installation

    FIrEPLACE INStALLAtION Step 2. Level the firebox by checking the top rOutING GAS LINE edge of the firebox. Shim if necessary. Step . Frame these appliances as illustrated in Route a 1/2" (13 mm) gas line along the inside Step 3. The fireplace should be secured to the Figures 7 through 9.
  • Page 8: Fireplace Specifications

    FIrEPLACE SPECIFICAtIONS dimensions - Inches (millimeters) Model No. 4-3/4 23-/2 E36OdG (940) (06) (597) 47-3/4 29-/2 E42OdG (092) (23) (749) (508) Weight And Volume Model Ship. Weight (lbs) Shipping Volume 35 Cu. Ft. E36OdG 200 lbs top View E42OdG 38 Cu. Ft. 230 lbs top Stand-Off Spacers (4...
  • Page 9: Framing Specifications

    FrAMING SPECIFICAtIONS Opening E360DG E420DG Back Wall Of Corner Installation Chase/Enclosure 42-3/4" (1086) 48-3/4" (1238) Including Finishing 46-1/2" (1181) 46-1/2" (1181) Materials If Any 23-9/16" (599) 29-9/16" (751) 11-1/4" (286) 14-1/4" (362) 63-1/2" (1613) 69-1/2" (1765) 31-3/4" (807) 34-3/4" (883) 20-1/2"( 521) 20-1/2"( 521) 44-3/16"...
  • Page 10: Field Wiring

    FIELd WIrING SPArK tO PILOt IGNItOr INtErMIttENt ELECtrONIC WIrING dIAGrAM Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. IGNItOr MOduLE Refer to Figure 10 for the wiring schematic for these fireplaces.
  • Page 11: Connecting Gas Line

    CONNECtING GAS LINE Gas Flex Line Connector Codes require a shut-off valve mounted in the 3/8" NPt x 3/8" /2" x 3/8" Flare supply line. Figure 12 illustrates two methods Flare Fitting Shut-Off Valve Valve for connecting the gas supply. The flex-line method is acceptable in the U.S., however, Canadian requirements vary depending on 3/8"...
  • Page 12: Installing The Logs

    WArNING: dO NOt OPErAtE tHE FIrE- PLACE FOr ANy ExtENdEd PErIOd rear Log OF tIME WItHOut tHE LAVA rOCK IN PLACE. tHE PAN CAN OVEr HEAt ANd MAy WArP ANd tHE FIrEPLACE MAy SHut OFF AutOMAtICALLy. INStALLING tHE LOGS After verifying that the fireplace operates properly, replace the cover and set the bottom refractory components in place.
  • Page 13: Checking Appliance Operation

    CHECKING APPLIANCE OPErAtION Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. With gas line installed run initial system check- turn off the gas supply to the appliance and have it serviced by a qualified professional, as out before installing any additional accesso- it may not be operating correctly.
  • Page 14: Accessories And Components

    INStALLAtION ACCESSOrIES ANd COMPONENtS drain Pan The drain pan is used with the appliance. drain Pan Cat. No. Model description H465 dPSS36 drain Pan (36) H4652 dPSS42 drain Pan (42) NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
  • Page 15: Gas Conversion Kits

    GAS CONVErSION KItS WArNING: tHIS CONVErSION KIt SHALL BE AVErtISSEMENt: CEt ÉQuIPEMENt dE CONVErSION INStALLEd By A QuALIFIEd SErVICE AGENCy SErA INStALLÉ PAr uNE AGENCE QuALIFIÉE dE IN ACCOrdANCE WItH tHE MANuFACturEr'S SErVICE CONFOrMÉMENt Aux INStruCtIONS du INStruCtIONS ANd ALL APPLICABLE COdES ANd FABrICANt Et tOutES ExIGENCES Et COdES APPLI- rEQuIrEMENtS OF tHE AutHOrIzEd HAVING CABLES dE L'AutOrISÉS AVOIr LA jurIdICtION.
  • Page 16 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.

Table of Contents