PRODUCT SPECIFICATIONS
Shock and Vibration
PARAMETER
Mechanical Shock
Rotational Shock
Random Vibration
S w e p t S i n e V i b r a t i o n
10 - 300 Hz
Reliability Specifications
Annual Return Rate
< 1.0%
Quality Acceptance Rate
< 1,000 DPPM
Start/Stop Cycles
50,000
Data Reliability
< 1 per 10
14
bits read
Component Design Life
5 years (minimum)
3 – 4
OPERATING
30 Gs, 2.0 ms, no errors
10 - 45 Hz at 0.004 G
2
/Hz
48 - 62 Hz at 0.008 G
2
/Hz
2
65 - 300 Hz at 0.004 G
/Hz
301 - 500 Hz at 0.0006 G
2
/Hz
no errors
1 G (0 - peak) amplitude, .25 octave per minute
Annual Return Rate (ARR) indicates the average against products shipped.
ARR includes all reasons for returns (failures, handling damage, NDF), but
does not include inventory credit returns.
The quality acceptance rate indicates the percentage of Maxtor products
successfully installed by our customers, and/or the number of defective parts
per million (DPPM) encountered during the entire installation process.
This indicates the average minimum cycles for reliable start/stop function.
Data errors (non-recoverable). Average data error rate allowed with all error
recovery features activated.
Component design life is defined as a.) the time period before identified
wear-out mechanisms impact the failure rate, or b.) the time period up to the
wear-out point when useful component life expires.
NON-OPERATING
250 Gs, 2.0 ms, no damage
18,000 Rad/sec,0.5 - 1.0 ms, no damage
P S D :
10 Hz at .05 G
2
/Hz
2
20 Hz at .055 G
/Hz,
300 Hz at .05 G
2
/Hz
301 Hz at .0014 G
2
/Hz
500-760 Hz at .001 G
2
/Hz
877 Hz at .003 G
2
/Hz
1000-1570 Hz at .001 G
2
/Hz
2000 Hz at .0001 G
2
/Hz