5-2. ADJUSTMENT METHOD

Item Number 00 of device GEO
This explanation uses H-Position as an example.
1. Select "GEO 00 VSZ" with the 1 and 4 buttons.
2. Raise/lower the data with the 3 and 6 buttons.
3. Select the optimum state. (The standard is 1F for PAL reception.)
[MUTING]
4. Write with the
WRITE.)
5. Execute the writing with the - button. (The WRITE
display will be changed to red color while excuting, and back
to SERVICE.)
GEO
00
HPS
29
SERVICE 50
0
013Q
1.2M
59 FF
GEO
00
HPS
1F
WRITE
0
013Q
1.2M
59 FF
Written with [MUTING]
GEO
00
HPS
1F
SERVICE 50
0
013Q
1.2M
59 FF
Write executed with [0]
button. (The display changes to
GREEN
0
000A
Adjusted with [3]
and [6] buttons.
GREEN
50
0
000A
RED
The WRITE display
0
000A
then the display
returns to a green
SERVICE.
Use the same method for all Items. Use 1 and 4 to select the
adjustment item, use 3 and 6 to adjust, write with
then execute the write with -.
[WRITE]
Note : 1. In
, the data for all items are written into memory
together.
2. For adjustment items that have different standard data
between 50Hz or 60Hz, be sure to use the respective
input signal after adjustment.
3. Additional function to skip category (device) to category
(device).
example:
GEO
00
DAC
00
The buttons for the function above should be cursor +/–.
– 47 –
KV-ES34M81/ES34M91
[MUTING]
HPS
XXX
RM-916
,

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trinitron kv-es34m91

Table of Contents