Specification and performance data sheet

For filter models 9000 077 095 and 9000 077 096
Using replacement cartridge 9000 077 104
This model was tested by NSF
International as per ANSI/NSF
Standards 42 & 53 and was certified
for the reduction of the substances
listed below.
Models 9000 077 095 and 9000 077 096 were tested by NSF International in accordance with ANSI/NSF
Standard 53 and certified for cyst and cloudiness reduction. In addition, they were tested as per
ANSI/NSF Standard 42 and certified for the reduction of chlorine taste and smell.
Rated particle class:
Rated service life:
Substance
Average load in supply water
Cysts *
122,500 cysts/l
Turbidity
10.8 NTU
Rated value for
13,666,666 pts/ml
particle class I
w 0.5 to < 1 µm
Chlorine taste and
2.0 mg/l
smell
Substance
Max. permitted concentration in wastewater
Cysts *
N/A
Turbidity
0.5 NTU
Rated value for
N/A
particle class I
w 0.5 to < 1 µm
Chlorine taste and
N/A
smell
* Based on the use of Cryptosporium parvum oocytes.
Guidelines for use/water supply
parameters:
Water pressure
207
0.6 °C
Water temperature
Flow velocity
The system must be installed and
n
operated in accordance with the
manufacturer's guidelines.
The filter must be replaced every
n
6 months.
Flush new filters for 5 minutes.
n
For more details, see the guarantee
n
card.
20
The concentration of the specified
dissolved substances in the water that
reach the system was reduced to a
value equal to or below the permitted
limit value as stipulated by NSF/ANSI
42 and 53 for water drawn from the
appliance.
I
2800 litres
Permitted concentration as per
NSF
Min. 50,000 cysts/l
11 ± 1 NTU
Min. 10,000 particles/ml
2.0 mg/l ±10 %
Without adequate disinfection
before or after connection to the
system, this product should NOT be
827 kPa
used if the water has harmful
38 °C
microbiologic qualities or if its
quality is unknown. A system
0.75 gpm
certified for cyst reduction may be
(2.83 lpm)
used for disinfected water that
contains cysts that can be filtered
out, among other things.
Average reduction in %
99.99
98.8
99.00
97.5
Required reduction as per NSF
w 99.95 %
95.5 %
w 85 %
w 50 %
Information!
Although these tests were carried out
in standard laboratory conditions, the
actual performance of the appliance
might deviate from the values stated
here.
Average concentration in water
< 1 cyst/l
< 0.16 NTU
143,333 pts/ml
< 0.05 mg/l
NSF test report
J−00056513
J−00058972
J−00056506
J−00056501
The entire system (apart from the
cartridge) is subject to a one−year
warranty. In the case of the cartridges,
the warranty only covers
material/processing defects. The
service life of the cartridges depends
on the local water properties, so no
guarantee of service life is given.
For more information on the price of
spare parts, contact your local
appliance dealer or parts agent.
Manufactured by:
Cuno Engineered Products
1000 Apollo Road
Eagan, MN 55121−2240 U.S.A

Advertisement

Table of Contents
loading

Table of Contents