Download Print this page

American Standard Cartridge 78517 Installation Instructions

American standard faucet installation instructions

Advertisement

Quick Links

6
SERVICE
AERATOR may accumulate dirt causing distorted and reduced
water flow. Remove AERATOR. Clean AERATOR and FLOW
RESTRICTOR. Replace AERATOR.
If faucet drips, operate handle several times from "off" to "on".
Do not apply excessive force.
Clogged CARTRIDGE inlets may cause reduced flow in "full
on" hot or cold. To clean inlets, first turn off water supply,
then:
Remove HANDLE, CAP, HOT LIMIT STOP and CARTRIDGE.
Clean inlets and MANIFOLD.
Reassemble CARTRIDGE, alternately tightening screws. Replace
HOT LIMIT STOP , CAP and HANDLE. Check flow.
HANDLE
SET SCREW
HANDLE
BUSHING
CAP
HOT LIMIT
STOP
CARTRIDGE
SCREWS
CAP
RETAINER
For toll-free information and answers to your questions, call:
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
P r o d u c t n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A m e r i c a n S t a n d a r d I n c .
© A S A m e r i c a , I n c . 2 0 0 8
CARTRIDGE
SEALS
P0P-UP
ROD
7 8 5 1 7 Re v. 1 .1
HOT LINE FOR HELP
1-800-442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-12-00

Advertisement