Lervia KH 1150 Operating Instructions Manual

Ceiling fan with halogen lighting

Advertisement

IB_KH1150_E2731_UK_V1.qxd
15.01.2007
14:46 Uhr
Seite 1
UK
KOMPERNASS GMBH · BURGSTRASSE 21 · D-44867 BOCHUM
www.kompernass.com
ID-Nr.: KH1150-12/06-V1

Advertisement

Table of Contents
loading

Summary of Contents for Lervia LERVIA KH 1150

  • Page 1 IB_KH1150_E2731_UK_V1.qxd 15.01.2007 14:46 Uhr Seite 1 KOMPERNASS GMBH · BURGSTRASSE 21 · D-44867 BOCHUM www.kompernass.com ID-Nr.: KH1150-12/06-V1...
  • Page 2 IB_KH1150_E2731_UK_V1.qxd 15.01.2007 14:46 Uhr Seite 2 Ceiling Fan KH 1150 Operating Manual...
  • Page 3: Ib_Kh1150_E2731_Uk_V1.Qxd 15.01.2007 14:47 Uhr Seite

    IB_KH1150_E2731_UK_V1.qxd 15.01.2007 14:47 Uhr Seite 3...
  • Page 4 IB_KH1150_E2731_UK_V1.qxd 15.01.2007 14:47 Uhr Seite 4...
  • Page 5: Table Of Contents

    IB_KH1150_E2731_UK_V1.qxd 15.01.2007 14:47 Uhr Seite 3 Content Safety Instructions ................................4 Proper Use ..................................5 Product Overview................................5 Product Description ..............................6 Guide.....................................6 Installing the Ceiling Fan...............................7 Installing the Blade mounts (J) ..........................7 Installing the Extension Rod (B) ..........................7 Installing the Light Module (E) ..........................9 Removing the Transport Protection........................9 Installing the Blades (H).............................10 Hanging the Fan ..............................10...
  • Page 6: Safety Instructions

    IB_KH1150_E2731_UK_V1.qxd 15.01.2007 14:47 Uhr Seite 4 1 Safety Instructions DANGER :Always follow the safety instructions below. Otherwise, there is a significant risk of accidents. Danger of electric shock • Only a qualified electrician may connect the device to a pro- perly installed and earthed power line with a mains voltage from 220 - 240 V~ at 50 Hz.
  • Page 7: Proper Use

    IB_KH1150_E2731_UK_V1.qxd 15.01.2007 14:47 Uhr Seite 5 2 Proper Use The ceiling fan serves exclusively for promoting circulation. This ceiling fan is intended exclusively for use in private households. Observe all information in this installation and operating manual, in particular the safety instructions. Any other use is considered improper use.
  • Page 8: Product Description

    IB_KH1150_E2731_UK_V1.qxd 15.01.2007 14:47 Uhr Seite 6 4 Product Description The KH 1150 ceiling fan has three speed levels that are con- trolled with the pull chain. The direction can be changed with a switch, allowing the fan to blow air downward or draw it up.
  • Page 9: Installing The Ceiling Fan

    IB_KH1150_E2731_UK_V1.qxd 15.01.2007 14:47 Uhr Seite 7 6 Installing the Ceiling Fan WARNING: Follow the safety instructions (see Section 1) to avoid injuries or damage as a result of installation errors. Do not use the fan if it is damaged. NOTE: The letters in parentheses refer to the figure in Section 3 "Product Overview".
  • Page 10 IB_KH1150_E2731_UK_V1.qxd 15.01.2007 14:47 Uhr Seite 8 1b If you would like to use the short extension rod, pull the mount entirely off the long rod and slide it about halfway onto the short rod, as shown. 2 Step 1: Loosen the side screws of the connector (C) so that the extension rod can be inserted.
  • Page 11: Installing The Light Module (E)

    IB_KH1150_E2731_UK_V1.qxd 15.01.2007 14:47 Uhr Seite 9 6.3 Installing the Light Module (E) 1 Remove the three screws with lock washers from the light module (E). DANGER : Damaged cables lead to short- 2 Connect the cable plug of the light module to the socket circuits.
  • Page 12: Installing The Blades (H)

    IB_KH1150_E2731_UK_V1.qxd 15.01.2007 14:47 Uhr Seite 10 6.5 Installing the Blades (H) 1 Screw the blades firmly to the motor housing with 2 screws and washers each (see Fig.). 2 Slowly turn the fan for a few complete turns in order to check whether the blades are correctly installed.
  • Page 13 IB_KH1150_E2731_UK_V1.qxd 15.01.2007 14:47 Uhr Seite 11 2 Hang the fan in the installation plate, making sure that the mount lines up properly with the notch (see Fig.: circle). 3 Electrical connection DANGER : The electrical connection may only be performed by a qualified electrician! Colour coding: Green-yellow (I): PE conductor Failure to follow these instructions presents a life-...
  • Page 14: Operation

    IB_KH1150_E2731_UK_V1.qxd 15.01.2007 14:47 Uhr Seite 12 7 Operation 7.1 Setting the Speed Set the speed level with the pull chain (G) on the motor housing. Each pull changes the speed in the following sequence: Fast - medium - slow - OFF Switch the light on with the middle pull chain (F).
  • Page 15: Troubleshooting

    IB_KH1150_E2731_UK_V1.qxd 15.01.2007 14:47 Uhr Seite 13 9 Troubleshooting Problem/Fault Possible Cause(s) Remedy The fastening screws cannot be Replace the screws and nuts. Only screwed tightly or were turned too use screws that match the original far during installation screws; contact the manufacturer or retailer for information.
  • Page 16: Warranty And Service

    131 x 40 cm (35 cm with the shorter extension rod) Weight (incl.): 6750 g Labeled with testing certification: CE, GS 12 Importer KOMPERNASS GMBH BURGSTRASSE 21 D-44867 BOCHUM www.kompernass.com 13 Disposal Do not dispose of the device in normal domestic waste.
  • Page 17 IB_KH1150_E2731_UK_V1.qxd 15.01.2007 14:47 Uhr Seite 15...

Table of Contents