LOCATION REQUIREMENTS
Explosion Hazard
Keep flarnmabJe
materials
and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (460 ram) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
You will need:
[] A location allowing for proper exhaust installation.
See "Venting Requirements."
[] A separate 15 or 20 amp circuit for a gas dryer or 30 amp
circuit for an electric dryer.
[] If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer.
See "Electrical Requirements".
[] Floor must support dryer weight of 200 Ibs. (90.7 kg).
Also consider weight of companion appliance.
[] Cold water faucets located within 4 ft. (1.2 m) of the water
fill valves, and water pressure of 20 - 120 psi (138 - 827 kPa).
You may use the water supply for your washer using the
"Y" connector and short hose (if needed) which are provided.
[] Level floor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended
Dryer Feet Kit, Part Number 279810. If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
[] For garage installation, place dryer at least 18" (460 mm)
above floor. If using a pedestal, you will need 18" (460 mm)
to bottom of dryer.
[] The dryer must not be installed or stored in an area where
it will be exposed to water and/or weather.
iMPORTANT: Do not operate, install, or store dryer where
it will be exposed to water, weather, or at temperatures
below
40 ° F (4° C). Lower temperatures
may cause dryer not to
shut off at end of automatic sensor cycles, resulting in longer
drying times.
DRYER DiMENSiONS
Front view:
381/8
H
(968 rnrn)
+ -
3/411
_
(18 ram)
(686 ram)
©
©
* Approx.
measurement
Side view:
507/8"
(1292 turn)
311/8"
(790 turn)
3//411"
{18 ram)
53/4
I1.
(146 turn)
J
31/2,,
.+
+
(257 ram)
* Approx.
measurement
Back view:
53/4
H*
(146 ram)
+
++
3/4H
"k
(18 ram)
•,91--143/o" _
(365 mrn)
253/4"-i----_
(654 ram)
61/4"
(159 ram)
297/8 "*
(759 ram)
_4-61/o,,.
+
(156 ram)
Approx.
measurement
NOTE: Most installations
require a minimum of 5" (127 mm) clearance
behind dryer for exhaust vent with elbow. See "Venting Requirements".