Download Print this page

Product Dimensions - KitchenAid KECC568GBT0 Installation Instructions Manual

30" (76.2 cm) and 36" (91.4 cm) electric built-in ceramic cooktops

Advertisement

Available languages

Available languages

Before
you start...
Your safety and the safety of others
is very important.
We have provided many important safety messages
in this manual and on your appliance. Always read
and obey all safety messages.
This is the safety alert symbol. This symb01
alerts you to hazards that can kill or hurt
you and others. Aii safety messageswili be
preceded by the safety alert symbol and the word
"DANGER" or "WARNING"=These words mean:
Youca_ be killed or seriously injured if you don't
f0H0w instructions.
All safety messages will identify the hazard, teii you
how to reducethe chance of injury, and teli you
what can happen if the instructions are not
followed.
Proper installation is your responsibility. Make
sure you have everything for correct installation.
it is the responsibility of the installer to comply
with the installation clearances specified in these
instructions.
Cooktop
installed
over oven installation: Only
certain specified cooktop and oven models are
approved for cooktop over oven installations.
Cooktops approved for this type of installation
will have an approval label located on the outside
of the burner box. if you do not find this label,
contact your dealer to confirm that cooktop is
approved. The label on the bottom of your
cooktop lists the cooktop and oven combinations
that are approved for this type of installation.
Ovens approved for this type of installation will
have an approval label located on top of oven. if
you do not find this label, contact dealer to
confirm that oven is approved. Refer to oven
manufacturer's
installation instructions for
approval for built-under use and proper cutout
dimensions.
When installing cooktop
over a built-under
oven, Do Not fasten cooktop to countertop with
clamps. Cooktop then will be easy to remove if
servicing is ever necessary.
Check location
where cooktop will be installed.
The location should be away from strong draft
areas, such as windows, doors and strong
heating vents or fans. The cooktop should be
located for convenient use in the kitchen.
Grounded
electrical
supply is required. See
"Electrical requirements," Panel B.
Jraportant:
Observe all governing
codes and ordinances.
Failure to meet governing
codes and
ordinances
could lead to fire or electrical
shock.
When installing a cooktop under existing
cabinets and the installation does not meet the
minimum cabinet clearances. Install a range
hood above the cooktop to avoid burn hazards.
Countertop
opening
diraensions
that are
shown must be used. Given dimensions are
minimum clearances and provide required 0"
(0 cm) clearance.
New installations -- follow minimum
dimensions given.
RepJaceraent
installations
-- Be sure that
front edge of cooktop is at least 1-1/2"
(3.8 cm) back from front edge of countertop.
Jt is the customer's
responsibility:
To contact a qualified
electrical
installer.
To assure that the electrical
installation
is
adequate
and in conforraance
with National
Electrical
Code, ANSItNFPA 70 -- latest
edition**,
or CSA Standards
C22.1-94, Canadian
Electrical
Code, Part 1
and 022.2 No. O-[W91 - latest edition
*** and all
local codes and ordinances.
Product
dimensions
30" (7&2 cra} or
..........
.___-36"
(gl.4 cra} width
X
\
21" (83,3 era} depth
30" (76.2 era) or
...........
36" (91.4 cra) width
2W/8" (7.3 cra)
burner
box
height
both sides
21o5/16" (54.t era) depth
-----T
2=314" (7.3 cra)
burner
box
height
Cutout
dimensionstrequirements
18" (4S,7 cra) rain.
dearance
upper
cabinet
to countertop
within
minimum
clearances
to cooktop
\,
\
Do not seal
cooktop
to
countertop.
* Note: 24" (el cra) rain.
clearance
if bottom
of wood or
raetal cabinet
is protected
by
not less than 114" (O.O era}
flame retardant
raHIboard
covered
with not Jess than No.
28 MeG sheet steet, 0.015"
(0.04 era} stainless
steel, or
0.024"(0.08
cra) alurainura
or
0.020" (O.OS cra) copper.
30" (7&2 cra) rain. c{earance
between
top of cooking
platforra
and bottom
of
unprotected
wood or raetal
cabinet.
recoraraenaeo
/
I
clearances,
upper cabinet
depth
@
20o1/2';
($2 cra)
Junction
bow
12" (3O.S era)
[_
or more above
LJ
floor
and 10"
(25.4 era) from
right side of
cabinet.
Y
1" (2.5 cra) rain. distance
to
nearest
_eft and right side
eorabustibie
surface
above
eooktop.
Cooktop
width
A
B
30"
29=1/2"
30"
(76.2 cm)
(75 cm)
(76.2 cm)
36"
35-1/2"
36"
(91.4 cm)
(90.2 cm)
(91.4 cm)
36" (91,4 cra) or 30" (76.2 cra) rain. base
cabinet is required. Jf cabinet has a drawer, a
3" (7.5 cm) depth clearance from the countertop
to the top of the drawer (or other obstruction) in
the base cabinet is required.
Tools needed for installation:
Copies of the standards listed may be obtained from:
** National
Fire Protection
Association
Batteryraareh
Park
Quincy, Massachusetts
02269
*** Canadian
Standard
Association
178 Rexda_e Boulevard
Etobicoke,
(Toronto),
Ontario
Mew tR3
Panel A

Advertisement

loading

This manual is also suitable for:

Kecc568gwh0Kecc568gbl0Kecc568gal0Kecc568gbt1Kecc568gwh1Kecc568gal1 ... Show all