KitchenAid KEYS850LE2 Installation Instructions Manual

29" (73.7cm) electric dryer
Table of Contents

Advertisement

Available languages

Available languages

2Y'(73.7CM)ELECTRIC DRYER
INSTAIIATION INSTRUCTIONS
INSTRUCTIONSPOUR L'INSTAILATION DE LASECHEUSE
/
ELECTRIQUE DE 2Y'(73,7CM)
Table of Contents / Table des mati_res
DRYER SAFETY ...............................................
1
Sg:CURITE DE I.A Sg:CREUSE
.............................
16
INSTALLATION
INSTRUCTIONS.. .................. 2
Tools and Parts .................................
2
Location Requirements
........................
2
Electrical Requirements
- U.S.A ...............
4
Electrical Requirements
- Canada .............
5
Electrical Connection ...........................
6
Venting Requirements .................................
11
Plan Vent System ........................................
12
Install Vent System .....................................
13
Install Leveling Legs ....................................
13
Connect Vent.. ............................................
14
Level Dryer ..................................................
14
Reverse Door Swing (Optional) ................... 14
Complete Installation .......................
15
...................... 16
Outillage et pieces ................................
16
Exigences d'emplacement
.................................
17
18
19
Installation du systeme d'_vacuation
................. 21
Installation des pieds de nivellement. ................. 22
Raccordement
du conduit d'_vacuation .........
22
Mise h niveau de la s_cheuse .....................
22
Inversion de I'ouverture de la porte (facultatif) ... 22
Achever I'installation ...........................................
23
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided
many important
safety
messages
in this manual
and on your appliance.
Always
read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow
instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
8577189

Advertisement

Table of Contents
loading

Summary of Contents for KitchenAid KEYS850LE2

  • Page 1: Table Of Contents

    2Y'(73.7CM)ELECTRIC DRYER INSTAIIATION INSTRUCTIONS INSTRUCTIONSPOUR L'INSTAILATION DE LASECHEUSE ELECTRIQUE DE 2Y'(73,7CM) Table of Contents / Table des mati_res DRYER SAFETY ..........Sg:CURITE DE I.A Sg:CREUSE ......INSTALLATION INSTRUCTIONS....2 INSTRUCTIONS D'INSTALLATION ...... 16 Tools and Parts ......... Outillage et pieces ........ Location Requirements ......
  • Page 2: Instructions

    INSTALLATION INSTRUCTIONS Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Flat-blade screwdriver • Tin snips(new vent installations) #2 Phillips screwdriver • Caulking gun and Adjustable wrench that compound (for installing opens to 1"...
  • Page 3 Installation Clearances • Additional clearances might be required for wall, door and floor moldings. The location must be large enough to allow the dryer door to open fully. • For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Dryer Dimensions Louvered doors with equivalent ventilation openings are acceptable.
  • Page 4: Electrical Connection

    It is your responsibility If your outlet looks like this: To contact a qualified electrical installer. To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSl/NFPA 70-latest edition and all local codes and ordinances. The National Electric Code requires a 4-wire supply 4-wire receptacle (14-30t:?) connection for homes built after 1996, dryer circuits involved...
  • Page 5 If you are using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 3394208. For further information, please reference the service numbers located in the Dryer User Instructions. GROUNDING iNSTRUCTiONS • For a grounded, cord-connected dryer: This dryer must be grounded.
  • Page 6 Power Supply Cord Direct Wire Fire Hazard Fire Hazard Use t0 gauge solid copper wire. Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief. Use a UL listed strain relief. Disconnect power before making electrical connections. Disconnect power before making electrical connections.
  • Page 7 Put power supply cord through the strain relief. Be sure Electrical Connection Options that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with If your home has: And you will be Go to Section the dryer cabinet and be in a horizontal position.
  • Page 8: Venting Requirements

    Remove center silver-colored terminal block screw. 4-wire connection: Direct Wire Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and the neutral wire (white IMPORTANT: A 4-wire connection is required for mobile homes or center wire) of power supply cord under center, silver- and where local codes do not permit the use of 3-wire colored terminal block screw.
  • Page 9 Loosen or remove center silver-colored terminal block screw. Connect ground wire (green or bare) of power supply cable to external ground conductor screw. Tighten screw. Connect neutral wire (white or center wire) of power supply cord to the center, silver-colored terminal screw of the terminal block.
  • Page 10 Loosen or remove center silver-colored terminal block screw. Optional 3-wire connection Place the hooked end of the neutral wire (white or center wire) of power supply cable under the center screw of terminal Use for direct wire or power supply cord where local codes do block (hook facing right).
  • Page 11 Rigid metal vent • For best drying performance, rigid metal vents are recommended. • Rigid metal vent is recommended to avoid crushing and kinking. Flexible metal vent • Flexible metal vents are acceptable only if accessible for cleaning. Fire Hazard •...
  • Page 12 The angled hood style (shown here) is acceptable. • Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as 4" flowers, rocks or bushes, snow line, etc.). •...
  • Page 13: Connect Vent

    Determine vent path 1. Install exhaust hood. Use caulking compound to seal exterior • Select the route that will provide the straightest and most wall opening around exhaust hood. direct path outdoors. 2. Connect vent to exhaust hood. Vent must fit inside exhaust •...
  • Page 14 Insert screws into bottom holes on left side of cabinet. Tighten screws halfway. Position door so large end of door hinge slot is over screws. Slide door up so screws are in bottom of slots. 1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in Tighten screws.
  • Page 15: Level Dryer

    6. In the U.S.A. 8. Remove door strike (E) from cabinet. Use a small, flat-blade screwdriver to gently remove 4 hinge hole plugs (F) on left side • For power supply cord installation, plug into an outlet. For of cabinet. Insert plugs into hinge holes on right side of direct wire installation, turn on power.
  • Page 16: Instructions D'installation

    INSTRUCTIONSPOUR L'INSTAILATION DE LASECHEUSE ELECTRIQUE DE 2Y'(73,7CM) SECURITEDELASECHEUSE Votre s_curit_ et celle des autres est tres importante. Nous donnons de nombreux messages de securite importants dans ce manuel et sur votre appareil menager. Assurez-vous toujours lire tousles messages de securite et de vous y conformer. Ce symbole d'alerte de securite vous signale les dangers potentiels de deces et de blessures graves h vous et h d'autres.
  • Page 17: Exigences Concernant I'_Vacuation

    Dimensions de la s_cheuse 151/4, ' 223A,, ..__-' (38,74cm) (110cm) _'t_ I_ (70,5e! Risqued'explosion (73,66¢m) Garderles matieres et les vapeurs inflammables, telle que I'essence, loin de la s_cheuse. Placer la s_cheuse au moins 46 cm (18 po) au-dessus du plancher pour une installation dans 223/4"...
  • Page 18 Cette secheuse est equip6e d'un cordon electrique Exigences additionnelles concernant rinstallation dans une maison mobile homologue par la CSA International a introduire dans une prise murale standard 14-30R. Le cordon mesure 5 pi Cette secheuse peut _tre installee dans une maison mobile. (1,52 m).
  • Page 19 Conduit m_tallique rigide • Pour un meilleur rendement de sechage, on recommande d'utiliser des conduits metalliques rigides. • On recommande d'utiliser un conduit metallique rigide pour reduire les risques d'ecrasement et de deformation. Conduit m_tallique flexible • Les conduits metalliques flexibles sent acceptables seulement dans la mesure ou ils sent accessibles en vue du nettoyage.
  • Page 20 Installations standard du conduit d'6vacuation a raide d'un Le clapet incline de type boTte ci-dessous est acceptable. conduit m_tallique rigide ou souple 4" (10,2 cmS_ 21/2,, • (6,4 cm) Terminer le conduit d'evacuation par un clapet de decharge pour emp_cher les rongeurs et insectes d'entrer dans I'habitation.
  • Page 21: Planification Du Systeme D'_Vacuation

    Tableau des syst_mes d'_vacuation Dispositions sp_ciales pour les installations dans une maison mobile REMARQUE : Les installations d'evacuation du conduit par le Le syst_me d'evacuation dolt _tre solidement fixe a une section c6te ou par le bas comportent un changement de direction a 90 ° non combustible de la structure de la maison mobile et ne dolt I'interieur de la secheuse.
  • Page 22 Contr61er I'aplomb de la secheuse. Contr61er I'aplomb tout d'abord transversalement, puis dans le sens avant/arriere. Risque du poids excessif Utiliser deux ou plus de personnes pour deplacer et installer la secheuseo Le non-respect de cette instruction peut causer une blessure au dos ou d'autre blessure. Si la secheuse n'est pas de niveau, la deposer sur un bloc de 1.
  • Page 23 Porter_versible e xtra-large _ pivotement lateral 8. Enlever la g&che de la porte (E) de la caisse. Utiliser un petit tournevis a lame plate pour 6ter soigneusement 4 bouchons d'obturation (F) du c6te gauche de la caisse. Inserer les bouchons dans les trous de charniere du c6te droit de la caisse.
  • Page 24 9. Essuyer soigneusement le tambour de la secheuse avec un 11. Apres 5 minutes de fonctionnement, ouvrir la porte de la chiffon humide pour eliminer toute trace de poussiere. secheuse et voir s'il y a de la chaleur. En cas de chaleur, annuler le programme et fermer la porte.

This manual is also suitable for: