Installation Requirements - KitchenAid KEWS105BSS00 Installation Instructions Manual

24" (61 cm), 27" (68.6 cm), and 30" (76.2 cm) indoor/outdoor electric warming drawer
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION REQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions
provided with any tools listed
here.
Tools needed
Phillips screwdriver
Drill
13/8"(3.5 cm) hole saw
Parts supplied
4- #8-18 x %" screws
Lens (for panel ready models)
Check local codes. Check existing electrical supply. See
"Electrical Requirements."
It is recommended
that all electrical connections
be made by a
licensed, qualified electrical installer.
IMPORTANT:
Observe all governing codes and ordinances.
Cutout dimensions that are shown must be used. Given
dimensions
provide minimum clearance with warming drawer.
Recessed installation area must provide complete enclosure
around the recessed portion of the warming drawer.
Grounded electrical supply is required. See "Electrical
Requirements"
section.
Electrical supply outlet should be located in the rear wall on
the upper right-hand side of the cutout or in an adjacent
cabinet. The outlet must be recessed. If the electrical outlet is
located in an adjacent cabinet, a 13/8"(3.5 cm) minimum
diameter hole should have been drilled in the back of the
cutout or support surface to pass the power supply cord
through to the outlet.
Warming drawer support surface must be solid, level and
flush with bottom of cabinet cutout.
For best performance
results, make sure the warming drawer is
leveled before completing installation. There is no way to level the
warming drawer after it has been installed. If the installation is not
level, the door may slide open or not seal tightly, allowing heat to
escape.
NOTE: If installing the warming drawer below another product,
refer to that product's
literature for any installation requirements.
Product Dimensions
WARMING
OVERALL
RECESSED
RECESSED
DRAWER
WIDTH (A)
WIDTH (B)
HEIGHT (C)
SIZE
24" (61 cm)
233/4" (60.3 cm)
221/4" (56.5 cm)
9" (22.9 cm)
27" (68.6 cm)
263/4" (67.9 cm)
25V4" (64.1 cm)
9" (22.9 cm)
30" (76.2 cm)
293/4" (75.6 cm)
28V4" (71.8 cm)
9" (22.9 cm)
Cabinet Dimensions
Cabinet Side View
Warming
Support
surface
must be
drawer
_
solid, level, flush with
front
of cabinet cutout.
223/4"
(57.8 cm) _U
I
I-
recessed
_1
I
depth
2