Plan Vent System - Whirlpool WED7800XB0 Installation Instructions Manual

27" electric dryer
Table of Contents

Advertisement

improper venting can cause moisture
and lint to collect
indoors, which may result in:
[] Moisture damage to woodwork,
furniture, paint, wallpaper,
carpets, etc.
[] Housecleaning
problems and health problems.
Plan Vent System
Choose your exhaust
installation type
Recommended
exhaust installations
Typical installationsvent the dryer from the rear of the dryer.
A
...........................
S
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
E Rigid metal or flexible metal vent
G. Vent length necessary to connect elbows
H. Exhaust outlet
Optional exhaust installations
Fire Hazard
Cover unused exhaust holes with a manufacturer's
exhaust cover kit.
Contact your local dealer.
Failure to follow these instructions can result in death,
fire, electrical shock, or serious injury.
Exhaust Cover Kit (to cover unused exhaust holes):
Part Number W10186596 - all models
This dryer can be converted to exhaust out the right side, left side or
through the bottom. If you prefer, you may contact your local dealer
to have the dryer converted.
L ........_C'
.........
[..
A
B
C
A. Standard rear offset exhaust installation
B. Left or right side exhaust installation
C. Bottom exhaust installation
Alternate
installations
for close clearances
Venting systems come in many varieties. Select the type best for
your installation. Two close-clearance installations are shown. Refer
to the manufacturer's instructions.
A. Over-the-top installation (also available with one offset elbow)
B. Periscope installation
NOTE: The following kits for close clearance alternate installations
are available for purchase. Please see the "Assistance or Service"
section in your Use and Care Guide to order.
Over-the-Top Installation:
Part Number 4396028
Periscope Installation (For use with dryer vent to wall vent
mismatch):
Part Number 4396037 - 0" (0 mm) to 18" (457 mm) mismatch
Part Number 4396011 - 18" (457 mm) to 29" (737 mm)
mismatch
Part Number 4396014 - 29" (737 mm) to 50" (1.27 m) mismatch
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
S
11