Multitech MultiConnect User Manual page 122

Serial-to-serial adapter with ip
Hide thumbs Also See for MultiConnect:
Table of Contents

Advertisement

Register Unit
Range
S27
S28
S29
10 ms
0–255
S30
10 s
0–255
S31
Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
Chapter 10 − Modem Mode AT Commands, S-Registers, and Result Codes
Default
Description
73 (49Ah) General Bit-Mapped Options Status. Indicates the status of
command options.
Default:
Bit 2 Leased line control (&Ln)
0 =
Bits 4 - 5
0 =
1 =
2 =
Bit 6 CCITT/Bell mode select (Bn)
0 =
1 =
Bit 7 - Reserved
0
General Bit-Mapped Options Status. Indicates bit mapped options
status.
Default:
Bits 0 - 1
Bit 2 Reserved (always 0).
Bits 3 - 4
0 = 39%-61% make/break ratio at 10 pulses per second (&P0)
1 = 33%-67% make/break ratio at 10 pulses per second (&P1)
2 = 39%-61% make/break ratio at 20 pulses per second (&P2)
3 = 33%-67% make/break ratio at 20 pulses per second (&P3)
Bit 5-7 Reserved
70
Flash Dial Modifier Timer. Sets the length of time, in units of 10 ms,
that the modem will go on-hook when it encounters the flash (!) dial
modifier in the dial string. S29 is a country dependent parameter. The
S29 value cannot be changed using S29=XX. Default: 70 (700 ms)
for U.S.
0
Disconnect Inactivity Timer. Sets the length of time, in tens of
seconds, that the modem will stay online before disconnecting when
no data is sent or received. In error-correction mode, any data
transmitted or received will reset the timer. In other modes, any data
transmitted will reset the timer. The timer is inoperative in
synchronous mode.
192 (C0h) General Bit-Mapped Options Status. Indicates bit mapped options
status.
Default:
Bit 0 Single line connect message enable/disable (\Vn)
0 =
1 =
Bit 1 Reserved (0)
Bits 2-3
0 =
1 =
2 =
Bits 4-5
0 =
1 =
2 =
Bits 6-7
73 (49h) (01001001b)
Dial up line (&L0) (Default.)
Internal clock select (&Xn)
Internal clock (&X0) (Default.)
External clock (&X1)
Slave clock (&X2)
CCITT mode (B0)
Bell mode (B1) (Default.)
0
Reserved
Pulse dialing (&Pn)
192 (C0h) (11000000b)
Messages controlled by S95, Wn and Vn (\V0) (Default.)
Single line connect message (\V1)
Error correction progress messages (Wn)
DTE speed only (W0) (Default.)
Full reporting (W1)
DCE (line) speed only (W2)
Caller ID (+VCID)
Caller ID disabled (+VCID=0) (Default.)
Short (formatted) Caller ID enabled (+VCID=1)
Long (unformatted) Caller ID enabled (+VCID=2)
Reserved (Default = 11b)
122

Advertisement

Table of Contents
loading

Table of Contents