Ventilation System - Electrolux EI30BM5CHZC Installation Instructions Manual

Over the range microwave oven
Table of Contents

Advertisement

Available languages

Available languages

8 VENTiLATiON SYSTEM
(PREPARINGOVENFOB iNSTALLATiON)
This Over the Range
Microwave
Oven
is designed
for
adaptation to three types of hood ventilation systems. Select
the type required for your installation.
RECIRCULATING -- non-vented, ductless. Follow installation
procedure
(A). Recirculating
requires
the use of the
Charcoal Filters, which have already been installed in
the oven.
HORIZONTAL EXHAUST --
outside
ventilation.
Follow
installation procedure (B).
VERTICAL EXHAUST --
outside
ventilation.
Follow
installation procedure (C).
(A) RECIBCULATING:
NON-VENTED, DUCTLESS O PERATION
The unit is shipped assembled for recirculating.
NOTE:
1. The Exhaust
Damper
Assembly
is not required
for
recirculating exhaust.
2. The Charcoal Filters should be replaced every 6 to 12
months, depending on use.
Oven Light Cover
Oven Light
Hood Louver
(B)
1.
2,
HORIZONTAL EXHAUST: OUTSIDE VENTILATION
Remove 3 screws from back edge and 5 screws from the
top of Fan Cover Bracket. Save 3 screws to use them to
attach Exhaust Damper Assembly to the wall later and
discard remaining
5. Remove Fan Cover Bracket by
sliding it in the opposite direction of the arrow on the Fan
Cover Bracket, as shown in Figure 7.
Lift Hood Fan Unit carefully and slip wires out of cavity.
See Figure 8. CAUTION: Do net pull or stretch Hood Fan
Wire.
3. Rotate the Hood Fan Unit 180 ° so that the Fan Blade
Openings are facing the back of the oven. See Figure 9A on
page 5.
4. Replace Hood Fan Wire from (A) to (B). See Figure 9B
on page 5. Replace Hood Fan Unit into the oven. Be
careful not to pinch the Hood Fan Wire and the Hood
Fan Unit. See Figure 9C on page 5.
5. Put the wire back into cavity. See Figure 10A on page 5.
6. Assemble
the Exhaust Damper Assembly
to the Fan
Cover Bracket by sliding it into the slits in the same
direction as the arrow. Use 1 Tapping Screw 4 x 8 mm
from the INSTALLATION
HARDWARE
and tighten into
place. See Figure 10B on page 5.
7. This assembly
will be mounted to the Outside
Rear
Exhaust
cutout
in
future
instructions.
See
WALL
TEMPLATE for further procedures.
Fan Cover Bracket
L
FiguPe7
Figure GA
Upper Tab
HoodLouver (Inside)
Hood Fan Wire
/ / /
HoodFanUnit
/
/
Figupe8
FiguPeGg
®
4