Electrolux EI30ES55LWB Installation Instructions Manual page 7

30" gas slide-in range
Hide thumbs Also See for EI30ES55LWB:
Table of Contents

Advertisement

Available languages

Available languages

Direct
Electrical
Connection
to the
Circuit
Breaker,
Fuse Box
or Junction
Box
If the appliance is connected directly to the circuit
breaker, fuse box or junction box, use flexible, armored
or nonmetallic sheathed copper cable (with grounding
wire). Supply a U.L. listed strain-relief at each end of
the cable. At the appliance end, the cable goes through
the Direct Connection Hole (see Figure 5) on the Cord
Mounting
Plate. Wire sizes (copper wire only) and
connections must conform to the rating of the appliance.
Where local codes permit
connecting
the appliance-
grounding
conductor
to the neutral
(white)
wire
(see Figure 5):
1. Be sure that no power is supplied on the cable from
residence.
2. Remove the grounding strap from the terminal block
and from the appliance frame.
3. In the circuit breaker, fuse box or junction box:
a) Connect the green (or bare copper) wire, the white
appliance cable wire, and the neutral (white) wire
together.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
Cable from Residence
(W _Ji_!_/_Le _ _
_
X_/_rCeks
m
Green
U L-listed Conduit
(or BareCopper)
: ....
Connector (or CSA
Wire
Cablefrom
listed)
Appliance
NOTE: Be sure to remove the
supplied grounding strap.
Figure 5
3-Wire (Grounded
Neutral)
Electrical System
(Example:
Junction
Box)
Where local codes DO NOT permit
connecting
the
appliance-grounding
conductor
to the neutral
(white)
wire, or if connecting
to 4-wire
electrical
system (see Figure 6):
1.
Be sure that no power is supplied on the cable from
residence.
2.
Remove the grounding strap from the terminal block
and from the appliance frame.
3.
In the circuit breaker, fuse box or junction box:
a) Connect the white appliance cable wire to the
neutral (white) wire.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
d) Connect the green (or bare copper) grounding
wire to the grounding wire of the circuit breaker,
fuse box or junction box.
Cable from Residence
Green (or Bare
Copper) Wire
Red_
IX-,, "-_,
Green _
Copper) Wire
hite Wire
Black
i_,
Wires]
ite Wire
Junction
, _
_
u
-'_-
U.L.-'iste-' Conduit
BOX
Connector (or CSA
Cablefrom
listed)
Appliance
NOTE:Be sureto removethe
supplied grounding strap.
_"
Figure 6 - 4-Wire Electrical
System
(Example:
Junction
Box)
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents