Explosion
Hazard
Keep flammable materials
and vapors, such as
gasoline,
away from dryer.
Place dryer at least 18 inches (48 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion,
or fire.
You will need
A location that allows for proper exhaust installation. See
"Venting Requirements."
Aseparate
30-amp circuit.
If using a power supply cord, a grounded electrical outlet
located within 2 ft (61 cm) of either side of the dryer. See
"Electrical Requirements."
A sturdy floor to support the total weight (dryer and load) of
200 Ibs (90.7 kg). The combined weight of a companion
appliance should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire
dryer. (If slope is greater than 1" [2.5 cm], install Extended
Dryer Feet Kit, Part Number 279810.) Clothes may not tumble
properly and models with automatic sensor cycles may not
operate correctly if dryer is not level.
Do not operate your dryer at temperatures
below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be
exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes or
sleeping quarters. Contact your local building inspector.
Installation
Clearances
The location must be large enough to allow the dryer door to open
fully.
Dryer Dimensions
43 %"2
(110crn)
43%
(110crnl
"26"_
15W'
-(38.74cm)
(66 era)
A
..............
]
22%"
i
X
(73.66
crn)
*27%,,_
(70.Scrr
"27
'3/4"_'k
(70.5c_
\__T_
29''
(73.66crn)
D
A. Small opening side-swing
door
B. Large opening side-swing door
C. Wide opening side-swing door
D. Wide opening hamper door
*Most installations require a minimum 51/2'' (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Minimum
installation
spacing for recessed
area or closet
installation
The dimensions shown following are for the minimum spacing
allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
__1
_
LI_114 max.
(310 c m 2 )
18"
(45.7
24in. 2
--
_
._
(155cm2',
(0cm)
(73.66cm) (0crn)
(0cm) (70.5cm) (14cm)
A
B
__
3'j
(7.6 crn)
3
(7.6 cm)
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Additional spacing recommended