Power
Supply
Cord
Kit
The user is responsible for connecting the power supply
cord to the connection
block located behind the back
panel access cover.
This appliance may be connected by means of
permanent "hard wiring" (flexible armored or
nonmetallic shielded copper cable), or by means of a
power supply cord kit. Use only a power supply cord kit
rated at 125/250 volts minimum, 40 amperes minimum
and marked for use with ranges. See chart (below) for
cord kit connection opening size and rating information.
Cord must have either 3 or 4 conductors.
For mobile homes, new installations, recreational
vehicles, or areas where local codes do not permit
grounding through neutral, a 4 conductor power supply
cord kit rated at 125/250 volts minimum, 40 amperes
and marked for use with ranges should be used (see
Figure 4).
Terminals on end of wires must either be closed loop or
open-end spade lugs with upturned ends. Cord must
have strain relief clamp.
Risk of fire or electrical shock exists if
an incorrect
size range cord kit is used, if the
Installation
Instructions are not followed,
or if the
strain relief bracket is discarded.
Range Connection
Opening
Size Chart
Refer to chart below for proper range connection
opening size
and power supply cord kit ampere rating information
See serial
plate on range for kilowatt
rating data
Range Kilowatt
Rating
See Serial Plate on Range)
120/240 Volts
120/208 Volts
0-16.5 kW
0-12.5 kW
166-225kW
126-185kW
Diameter (inches) of Range
Minimum
Connection
Opening
Cord kit
Ampere
Direct
Rating
Cord Kit
Connection
40 Amp
I-3/8 in
I-1/8 in
50 Amp
I-3/8 in
I-3/8 in
NOTE: Range is shipped from factory with
1 1/8" dia. hole as shown in figure 3. If a larger hole
is required, punch out the knockout.
Electrical
Connection
to the
Range
This appliance is manufactured with the neutral terminal
connected to the range.
While connecting range, do not
loosen the nuts which secure the terminal
block to
the range. Electrical failure or loss of electrical
connection may occur.
Electrical
Shock Hazard
Electrical ground is required on this appliance.
Do not connect to the electrical supply until
appliance is permanently
grounded.
Disconnect power to the circuit breaker or fuse
box before making the electrical connection.
This appliance must be connected to a
grounded, metallic, permanent
wiring system,
or a grounding
connector should be connected
to the grounding
terminal or wire lead on the
appliance.
Do not use the gas supply line for grounding
the appliance.
Failure to do any of the above could result in a
fire, personal injury
or electrical shock.
Three
Conductor
Wire
Connection
to Range
(The 3-conductor
cord or cable must be replaced with a
4-conductor cord or cable where grounding through the
neutral conductor is prohibited in new installations,
mobile homes, recreational vehicles or in other areas
where local codes do not permit neutral grounding)
If local codes permit connection of the frame grounding
conductor to the neutral wire of the copper power supply
cord (see Figure 3):
1. Remove the 3 screws at the lower end of the rear
wire cover, then bend the lower end of the rear wire
cover (access cover) upward to expose range
terminal connection block (see Figure 2).
3-Wire Wall
Receptacle
3-Wire Power
Supply Cord Kit
Figure 1
To gain access to lower terminal
block bend lower back cover plate
along row of holes shown here
Figure 2
3