Direct
Electrical
Connection
to the Circuit
Breaker,
Fuse Box or Junction
Box
If the appliance is connected directly to the circuit breaker,
fuse box or junction box, use flexible, armored or nonmetallic
sheathed copper cable (with grounding
wire). Supply a U.L.
listed strain-relief
at each end of the cable. At the appliance
end, the cable goes through the Direct Connection
Hole (see
Figure 7) on the Cord Mounting Plate. Wire sizes (copper
wire only) and connections
must conform to the rating of the
appliance.
Where local codes permit connecting
the appliance-
grounding
conductor to the neutral (white) wire (see
Figure 8):
1. Be sure that no power is supplied on the cable from
residence.
2. Follow instructions
on previous page for Four Conductor
Wire Connection
to Range (Fig. 7).
3. In the circuit breaker, fuse box or junction box (Fig. 8):
a) Connect the green (or bare copper) wire, the white
appliance cable wire, and the neutral (white) wire
together.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
Cable from Residence
Neutral
""--"?
(white) Wire
._
,----
Black
Rerde s
_
Red
'::::_--_
! _Wires-
--__
1 _--'-
Junction
Box
White Wire
Green
U.h-listed
Conduit
(or Bare Copper)
:
Connector (or CSA
Wire
Cable from
listed)
Appliance
NOTE: Be sure to remove the
supplied grounding strap.
Figure 8
3=Wire (Grounded Neutral)
Electrical
System
(Example: Junction
Box)
Where local codes DO NOT permit connecting
the
appliance=grounding
conductor to the neutral (white)
wire, or if connecting
to 4=wire electrical
system
(see
Figure 9):
1.
Be sure that no power is supplied on the cable from
residence.
2.
Follow instructions
on previous page for Four Conductor
Wire Connection
to Range (Fig. 7).
3.
In the circuit breaker, fuse box or junction box (Fig. 9):
a) Connect the white appliance cable wire to the neutral
(white) wire.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
d) Connect the green (or bare copper) grounding
wire to
the grounding wire of the circuit breaker, fuse box or
junction box.
Cable from Residence
Green (or Bare
Copper) Wire
Red_,
[[_
]-"_,
Green (or Bare tL[_i(
"_
Copper) Wire _
hite Wire
Black
_
Wires 1
_
White Wire
Junction
_U.L.-listed
Conduit
Box
.....
Connector (or CSA
Cable from
listed)
Appliance
NOTE: Be sure to remove the
supplied grounding strap.
_"
Figure 9 - 4=Wire Electrical
System
(Example:
Junction
Box)
7. Checking
Operation
Refer to the Use and Care
Guide
for operation.
_Do
not touch
cooktop
glass or elements.
They may be hot enough
to burn you.
Before
You Call for Service
Read the Before You Call for Service
Checklist
and
operating
instructions
in your Use and
Care Guide.
It may save you time and expense.
The list includes
common
occurrences
that are not the result of
defective
workmanship
or materials
in this appliance.
6

Advertisement

Table of Contents
loading

Table of Contents