ExhaustInformation
WARNING:
TO REDUCE THE RISK OF FIRE
AND PERSONAL INJURY
• Use only metal duct for exhausting
dryer to outdoors.
• Do not terminate exhanst in a chimney, any gas vent,
under an enclosed floor (crawl space), or into an attic.
The accumulated lint could create a fire hazard.
• Provide an access for inspection and cleaning of the
exhaust system, especially at turns. Inspect and clean
at least once per year.
• Never terminate the exhaust into a common duct with
a kitchen exhaust. A combination
of lint and grease
could create a fire hazard.
• Do not obstruct incoming or exhausted air.
Rear Exhaust Location
This dryer comes ready for rear exhausting. If space is limited,
use the following instructions to exhaust directly from the side
or bottom of the cabinet.
298 mm (1PA")
90 mm (31/2' ')
NOTE:Add to vertical d#aension the
distance between cabinet bottma
and floor surface,
Steps to Change Dryer to Side or Bottom Exhaust
Directly on Cabinet
WARNING:Protect yourhandsand armsfrom sharp edges
when working inside the dryercabinet.
1. Detach and remove the desired knockout.
2. Remove the screwinside
the
,,
B
A
dryer exhaust duct end. Keep
i
1
the screw for step 5. Pull on
Fixing hole
L229 mm
the duct to remove it.
3. Cut the duct as shown. Keep portion A.
4. Through
the rear opening,
h)cate the tab in the
nfiddle of the (hTer base. Lift the tab to about 45 °
using a fiat s(rewdriver.
Onlymetal
I
;
duct may be
I
1
I
used inside the
[
I
dryer cabinet
Blower housing
........
i%:
,29mm,9",J
,
Cut portion
285 rnm
216mm
(11%")_1
(8V[')
of side
121 mm (4aA ")
121mm (4 W')
5. Reconnect
and secure the cut portion
(A) of the duct
to the blower housing. Make sure the fixing hole is
aligned with the tab in the base. Use the s(iew flOln
step 2 to secure the duct in place through the tab on
the &Ter base.
6. Use standard metal elbows and duct to complete
the exhaust system. Insert standard elbows and ducts
through rear and side or bottom openings.
7. (over the opening at the back with the plate (Kit
WEIM454) available flOln your h)cal serxfce prox4der.
WARNING: N EVER LEAVE THEBACK OPENING WITHOUT THEPLATE.
Exhaust Length
The MAXIMUM AIA_€)'v\LMH_Elength of the exhaust
system depends
upon the type of duct, number
of turns,
type of exhaust hood (wall cap) and all conditions
noted
below. The maximum
allowable length fin both rigid and
fexible
metal duct is shown in the table below. More that
two 90 o turns are not recommended.
FORELECTRIC
DRYERONLY
RECOMMENDED MAXIMUM LENGTH
Weather Hood Type
Recommended
Use only for
Number of
90 ° elbows
0
1
2
Do
not use
non-metallic
flexible
duct.
10 cm(4")
Rigid
Flexible
Metal
10.7m (35ft) 7.6m(25ft)
9.1m(30ft) 4,6m(15ft)
6.1m(20ft) 3.0m(10ft)
short run
installations
_--_ 6 cm (2W')
Rigid
Flexible
Metal
7.6m(25ft)
4.0m(13ft)
4.6m(15ft)
3.0m(10ft)
3.0m(10ft)
Hood or Wall Cap
• Terminate
in a manner
to prevent ba(k drafts or enu T
of birds or other wildlife.
Termii_ation
should
present
mildmal
resistan(e
to the exhaust
airflow
and
should
require
little
or no maintenan(e
to prevent
(logging.
Never
install s(reen
over exhatlst
(hi(l,
Wall caps must be installed
at least 300 mm(12")
above ground
level or any other obstruction
with the
opening
pointed
down.
If root vents or louvered plenums are used, they must be
equivalent to a 100 mm (4") dampered
wall cap in regard
to resistance to airflow, prevention of back drafts and
maintenance
required to prevent clogging.
Separation of Turns
For best performance, separate all turns by at least 1.2 m
(4') of straight duct, including
distance
between last turn
and dampered
wall cap.
Turns Other Than 90 °
• One turn of 45 ° or less may be ignored.
• Two 45 ° turns should be treated as ()tie 90 °.
• Each turn over 45 ° should be treated
as one 90 °.
Sealing of Joints
• All joints should be tight to avoid leaks. The male end
of each section of duct must point mvay fiom the dtTer,
• Do not assemble
the duct work with tasteners
that
extend into the duct, They will serve as a collection
point lot lint.
• Duct joints can be made air- and moisture-tight
by
wrapping
the overlapped
joints with duct tape.