Download Print this page

Provide An Adequate Gas Supply; Seal The Openings; Connect The Range To The Gas Supply - Kenmore 79036693501 Installation Instructions Manual

30" gas slide-in range

Advertisement

Available languages

Available languages

Countertop
Preparation
• Tile cooktop sides of tile range fit over tile cutout edge
of your countertop.
• If you have a square finish
(flat) countertop,
no
countertop
preparation is required. Cooktop sides lay
directly on edge of countertop.
Formed front-edged
countertops must have molded
edge shaved flat 3/4" (1.9 cm) from each front comer
of opening (Figure 2).
• Tile countertops
may need trim cut back 3/4"(1.9
cm) from each front corner and/or rounded edge
flattened (Figure 2).
(1.9cm)
J
_J
311/_,,//
(81 cm)
Formed or tile countertop
trimmed
%" (1.9 cm) back at
front
corners
of countertop
(1.9 cm)
opening.
[
Figure 2
• tf the existing
cutout
width
is greater
than
30-!/16"
(76,4 cm), reduce the 3A" (!.9 cm)
dimension.
Provide
an adequate
Gas Supply
When shipped from the factory, this unit is designed to
operate on 4"(!0,!6
cm) water column (I .0 kPa) Natural
gas manifold pressure. A convertible pressure regulator is
connected to the range manifold and MUST be
connected in series with the gas supply line. If LP/
Propane conversion kit has been used, follow instructions
provided with tile kit for converting the pressure
regulator to LP/Propane use.
Care must be taken during installation of range not to
obstruct tile flow of combustion and ventilation air.
For praper operation, the maximum inlet pressure to tile
regulator should be no more than 14"(35,56 cm) of
water column pressure (3.5 kPa). The inlet pressure to
the regulator must be at least I " (.25 kPa) greater than
the regulator manifold pressure setting. Examples: If
regulator is set for natural gas 4"(10,16 cm) manifold
pressure, inlet pressure must be at least 5"(12.60 cm); if
regulator has been converted for LP/Propane gas
10"(25,4 cm) manifold pressure, inlet pressure must be
at least 11 "(27,9 cm).
Leak testing of the appliance shall be conducted
according to the instructions in step 4.
The gas supply line should be _/2" or ;A" I.D. (Interior
Diameter)
Countertop
must be level. Place a level on the
countertop, first side to side, then front to back. If the
countertop is not level, the range will not be level. The
oven must be level for satisfactory baking results.
Cooktop sides of range fit over edges of countertop
opening.
For existing
cutout width of 29" (73.7 cm) (Figure 3):
2 3/16"
(73.7
cm)
30" /
(76.2 cm)
(3.2 (m)
Seal the openings
Seal any openings in the wall behind the range and in the
floor under the range after gas supply line is installed.
Connect the range to the gas supply
Important:
Remove all packing material and
literature from range before connecting gas and
electrical supply.
To prevent leaks, put pipe joint sealant on all external
pipe threads.
Your regulator is in location
shown below.
You must also clear 2 3/16"
(5.56 cm) of material
from
front
of countertop.
31W 'j
(81
cm)
./--
_Formed
or tile countertop
trimmed
11/4"
(3.2 cm) back at front
corners
of
countertop
opening.
Figure 3
4
Figure
4
PRESSUR REGULATOR
LOCATION
Do not
aI[ow
regulator
to
rotate
on pipe
when
tightening
fittings.

Advertisement

loading