D-Link DVG-3016S User Manual page 47

Voip gateway
Hide thumbs Also See for DVG-3016S:
Table of Contents

Advertisement

DVG-3016S/3032S User's Manual
UDT Detection
If the CPT auto detect function is not able to determine whether or not a PSTN-call receiving party has hung
up the phone, then the UDT detection function can serve as a back up. To do this, enter the high/low
frequency parameters from the CPT table into the UDP table.
NOTE: If FXO cut off calls un-normally, please disable this function.
D-Link Systems, Inc.
CPT/Cadence Settings
44

Advertisement

Table of Contents