Connecting The Wires To The Terminals
21
Tip: Press and hold the AHEAD/BACK or UP/DOWN key to move the numbers quickly.
SET
Program 1
AM
Figure 1
Figure 3
SET
Program 1
Figure 4
Figure 2
8
Wall
Back-Cover
Through Hole
Wall
Wires
Wires
Back-Cover
+ +
+
+
+ +
+ +
+ +
Terminals
SET
HE AT
Temperature
Weekday
AM
Hour/Minute Setting
SET
HE AT
Temperature
Weekend
AM
Hour/Minute Setting

Heating Program

Slide the system switch to the HEAT position and press the PROGRAM key once, the P1 and
SET symbols will appear on the display. MO to FR symbol is shown indicating Weekday program
is being displayed. (Figure 3)
Use AHEAD or BACK to select the desired start time for weekday program 1.
Use UP or DOWN (on extreme right) to set the desired temperature.
Temperature can be set in increments of 0.5°.
Program time can be set in increments of 10 minutes.
After setting correct time and temperature for program 1, press PROGRAM again to display
weekday program 2. Use same method to set the desired time and temperature for program 2.
Repeat the procedures for weekday program 3 and 4, and weekend programs 1-4. (Figure 4)
After complete setting of all 8 programs, press PROGRAM to return to normal display (SET
symbol will disappear). Leaving the thermostat without any keys pressed for 16 seconds while
setting will also return the display to normal.
Note:
The PROGRAM key can also be used anytime to review all the set programs.
To terminate the programming sequence at anytime, press DISPLAY key.
7
Mounting The Thermostat Back-Cover
The back-cover should be mounted horizontally
with the terminals on the left side.
Thread the existing wiring through the big center
hole from the back and set the back-cover
horizontally on the wall.
Select two appropriate mounting holes and mark
the locations with a pencil. If necessary, use a level
to make sure the thermostat is leveled.
Remove the back-cover from the wall and drill two
3/16 inch holes in the marked screw positions.
Insert the wall-anchors into the holes completely. If
necessary, use a hammer to tap-in lightly.
Mount the back-cover with the two screws to the
wall. Make sure the metal terminals are on the left
side.