TROUBLESHOOTING - BRUSH MOTOR WILL NOT TURN
(continued)
If 0 voltage is read at the brush switch check the circuit board located in the upper handle.
Check that connections are secure. If 110/120 volts AC goes into the board (red & white
wires) and a reading other than 100 – 150+ volts DC goes out, then the circuit board is
defective and requires replacement. There is a breaker on the circuit board. Cycle the
unit on and off to see if breaker resets.
Check for 120 volts AC
Circuit Board
Issued: September, 2005
© 2005 BISSELL Homecare, Inc.
Bissell ProHeat 2X™ Service Center Guide