8-34 Troubleshooting
Maintenance Tools with Remote Console
This subsection describes the procedures for using Maintenance Tools with remote console.
Maintenance Tools contains the remote console feature that allows the system administrator to set
up the server from the management workstation (management PC) via the network or the server's
COM B (serial) port.
IMPORTANT:
Do not use this feature on any other computer than the server, or on
any other server obtained without the NEC EXPRESSBUILDER.
Doing so may cause a failure of the server.
Select "Maintenance Tools (Redirection mode)" for the remote
console in the "Boot Selection" menu. Even if the rest is selected, it
does not display it in management PC.
The system may fail to operate with the transfer rate of 115.2 Kbps
for serial console redirection. Specify any other transfer rate than
115.2 Kbps.