  • Page 1: Table Of Contents

    B. Application C. Features Include D. Safety Instructions USER MANUAL E. Front View Main Functions F. Rear View Main Functions G. Pre-Installation Information MODEL: PM-0350L H. Electrical Requirements I. Installation Requirements PM-0650L J. Connection And Testing K. Operation PM-1000L L. Green Power Adjustment PM-1200L M.
  • Page 2: General Introduction

    A. General Introduction We are experts in Compact High and Low Frequency Power Inverters. Our engineers are making use of advanced high frequency design that results in an inverter that is smaller, lighter, and easier to use than any other inverter with similar power ratings. We have been developed to provide you with years of trouble free operation.
  • Page 3: Front View Main Functions

    • Do not expose the Inverter to rain, snow, spray, bilge or dust. • To reduce risk of hazard, do not cover or obstruct the ventilation openings. • Do not install the Inverter in a zero-clearance compartment. Overheating may result. •...
  • Page 4: Rear View Main Functions

    1. ON / OFF switch: Power ON/OFF switch, leave in the OFF position during installation. 2. LED INDICATION: OVER VOLT: Over voltage protection. OVER TEMP: Over Temperature Protection. UNDER VOLT: Under voltage protection. OVER LOAD: Over Load Protection. POWER: Power ON. RUN/GREEN POWER: Indicates current operating condition of the inverter. 3.
  • Page 5: Pre-Installation Information

    WARNING! Shock Hazard! Before proceeding Further, ensure that the Inverter is NOT connected to any Batteries, and that all wiring is Disconnected from any electrical Sources. Do not connect the output Terminals of the Inverter to an incoming AC sources. G.
  • Page 6 AC utility source. The AC output ground wire should go to the grounding point for your loads ( for example, a distribution panel ground bus ). 3. Neutral Grounding: 120V models: The neutral conductor of the AC output circuit of the Inverter is automatically connected to the safety ground during inverter operation.
  • Page 7: Connection And Testing

    GFCI protection of certain receptacles in residential installations. While the output of the Inverter is equivalent to the waveform provided by utilities, compliance with UL standards requires us to test and recommend specific GFCI’s. State power has tested the following GFCI-protected 15A receptacles and found that they functioned properly when connected to the output of the Inverter.
  • Page 8 WARNING! Make sure all the DC connections are tight (torque to 9-10 ft-lbs,11.7-13Nm). Loose connections will overheat and could result in a fire hazard. 3. Before proceeding further, carefully check that cable you have just connected the positive terminal of inverter to the positive terminal of the power source. CAUTION! +...
  • Page 9: Operation

    K. Operation: To operate the power inverter, turn it on using the ON/OFF switch on the front panel. The power inverter is now ready to deliver AC power to your loads. If you are operating several loads from the power inverter, turn them on separately after the inverter has been turned on.
  • Page 10: Trouble Shooting

    keep the inverter ON all the time: this could be used if you have a very small load that must stay ON at all times. • Adjust the pot until the lamp is steady green, then turn the pot back a little until the lamp flashes green.
  • Page 11: Maintenance

    • Do not operate high power loads with the power inverter while watching television. • Make sure that the antenna feeding your television provides an adequate (“Snow free”) signal and that you are using good quality cable between the antenna and the television. •...
  • Page 12: Specifications

    O. Specifications PM-0150L-12 1 E 0150 WATT 0350 WATT TYPE 0650 WATT INPUT 1000 WATT A – N. American 12 VDC OUTPUT 1200 WATT B – U.K. 24 VDC 1 – 110 V 1800 WATT C – Australia 48 VDC 2 –...

This manual is also suitable for:

Pm-0650lPm-1800lPm-1000lPm-3000lPm-1200l

Table of Contents