Clearances around the Boiler (Figs. 18 & 19)
1. The minimum clear spaces needed around the boiler
measured from the casing are as follows:
Top
-
200mm
Bottom
-
200mm
Left Side
-
5mm
Right Side -
20mm/5mm*
Front
-
5mm
-
450mm
*NOTE: The boiler can be operated with a clearance
of 5mm at the right. This is also sufficient for routine
maintenance. However a clearance of 20mm is
required if it is necessary to remove the secondary
heat exchanger. This should be considered when
siting the appliance and in the event of any
subsequent alteration in the area of installation.
2. These areas must not be obstructed in any way.
Blocking the clearance spaces may result in the
boiler overheating and damage may occur.
3. The gas burning compartment of your boiler is
completely sealed from the room in which it is fitted.
Products from the combustion of gas are vented to the
outside through the flue terminal which must be kept
free from obstruction as this would interfere with the
correct operation of the boiler.
4. The boiler may be installed in a cupboard if these
minimum clearances are kept. The compartment
should be large enough to house the boiler and
ancillary equipment only.
5. IT SHOULD NOT BE USED AS A STORAGE
CUPBOARD.

Check List

1. If a fault develops, or is suspected, call your Installer
or Service Engineer as soon as possible.
2. Go through the following check list before you make
contact.
a)
Is the electricity supply on ?
b)
Is the selector switch in the On Position (giving a
green "Power On" neon) ?
c)
Is the red "Flame Failure" neon lit ? Turn the
On/Off/Reset selector fully anti-clockwise.
d)
Is the gas supply on ?
e)
Is the system pressure correct ?
f)
Is the boiler temperature control set high enough ?
g)
Is the time clock (if fitted) calling for heat ?
h)
Is the room thermostat (if fitted) set high enough ?
i)
Are the radiator valves open ?
Publication No. 5111818
(In Operation)
(For Servicing)
Fig. 18
Fig. 19
5mm Min
450mm Min
For Servicing
Purposes
5mm Min
In Operation
20mm/5mm Min
450mm
see *NOTE:
200mm Min
780mm
200mm Min