Install Vertical Termination Baffl E - Heatilator D4236R Owner's Manual

Direct vent gas appliance
Table of Contents

Advertisement

F. Install Vertical Termination Baffl e
Note: For vertically terminated installations only.
Note: If installing a vertical vent/termination run off the
top or rear of the appliance, the vertical termination baffl e
supplied with the appliance may be used.
Remove the glass (refer to Section 14.J.) to access the
fi rebox and 5 in. inner fl ue.
Fold the baffl e (Figure 7.17) to an approximate 90°
angle (see Figure 7.18).
Figure 7.17 Flat Baffl e
Figure 7.18 Baffl e Bent to 90° Angle
32
Heatilator • Caliber CD Series • 4040-263 Rev M • 06/08
Squeeze the open end of the bent baffl e with one
hand. Insert the baffl e bent side up into the inner fl ue
so that the bottom of the baffl e is above the bead on
the inside of the collar. See Figure 7.19.
Figure 7.19 Placing the Baffl e
Release pressure on the baffl e so that it is wedged
against the sides of the fl ue collar. See Figure 7.20.
Figure 7.20 Baffl e in Place
Replace the glass (refer to Section 14.J.).
Start the appliance.