  • Page 1 INSTALLATION TIPS & USER GUIDE CENTRAL VACUUM POWER UNIT FOR RESIDENTIAL USE ONLY AB0001 VX3000C, VX6000C VX12000C ODELS ISIT WWW BROAN CA FOR THE ENTRAL ACUUM YSTEM NSTALLATION NSTRUCTIONS .; M 1-888-882-7626 ROAN ANADA ISSISSAUGA NTARIO BROAN EGISTER YOUR PRODUCT ONLINE AT...
  • Page 2: Important Safety Instructions

    page 2 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE CAUTION HEN USING AN ELECTRICAL APPLIANCE BASIC PRECAUTIONS DO NOT REMOVE either of the TOP red cap plugs SHOULD ALWAYS BE FOLLOWED INCLUDING THE FOLLOWING that are glued to the unit.
  • Page 3: Table Of Contents

    WARRANTY ..................16 CENTRAL VACUUM SYSTEM INSTALLATION INSTRUCTIONS Please visit www.broan.ca for the Central Vacuum System Installation Instructions System Planning and Layout,...
  • Page 4: General Information

    AR0040 MAKING A JOINT COMPLETING THE INLET ASSEMBLY AO0010 INLET MOUNTING CEMENTING FLEXIBLE TUBING PLATE AE0024A INSTALLING THE INLET SECURE WIRE TO TUBING AO0045 For more details on inlet installation, visit www.broan.ca for the Central Vacuum System Installation Instructions. AO0011...
  • Page 5: Power Unit Installation

    WALL MINIMUM CLEARANCE DIMENSIONS 24” 24” TOP VIEW 30⅜” 30⅜” Broan VX3000C: 11” 3/4” TYP. Broan VX6000C and VX12000C: 13¾” MOUNTING HOLES 24” MINIMUM TO CEILING UTILITY VALVE 12⅝” ⁄ ”...
  • Page 6: Internal Wiring Diagrams

    • VX3000C • VX6000C WHITE BLACK GREEN GREEN 120 VOLTS CAUTION BLUE Broan VX3000C, VX6000C and VX12000C power BLUE THERMAL CONTROL PROTECTOR units will attach to the lower intake connections. BLACK BOARD See Fig. 10. Utility valve can be installed on either side.
  • Page 7: Grounding Instructions

    – if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Fig. 4 Fig. 5 Broan VX3000C & VX6000C NOTE: INLET LEADS TO BE CONNECTED TO POWER UNIT TERMINALS USING CRIMP CONNECTORS AND LOW VOLTAGE WIRE HARNESS.
  • Page 8: For Models: Vxkit300A, Vxkit600E And Vxkit1200E

    page 8 FOR MODELS: VXKIT300A, VXKIT600E AND VXKIT1200E INSTALLING HOSE HANGER CONNECTING HOSE ’ CONT DUAL VOLTAGE HOSE IMPORTANT: Do not return the hose to the store. OPERATING HANDLE SWITCH LOW VOLTAGE HOSE DUAL VOLTAGE HOSE CONNECTING HOSE LOW VOLTAGE HOSE...
  • Page 9: For Models: Vxkit600E And Vxkit1200E

    page 9 FOR MODELS: VXKIT600E AND VXKIT1200E HOW TO ASSEMBLE POWER BRUSH/WAND/HANDLE CAUTION Always check underside of product for any obstructions prior to use. WARNING Never leave electric power brush unattended while it is plugged in. ANDLE TO ONNECTION AND TO OWER RUSH ONNECTION...
  • Page 10 page 10 HOW TO USE POWER BRUSH/WAND EDGE CLEANER CAUTION Always pick up hard or sharp objects by hand before using your power brush. Items such as pins, ELECTRONIC CIRCUIT BREAKER hairpins, tacks, crayons, etc., may damage the brush roll or may break the belt. WAND RELEASE AD0030 CAUTION...
  • Page 11: Maintaining The Power Brush

    page 11 MAINTAINING THE POWER BRUSH HOW TO CHANGE BRUSH ROLL WARNING Disconnect electrical supply before servicing or cleaning the unit. Failure to do so can result in Fig. 6 electrical shock or personal injury from cleaner suddenly starting. Fig. 7 HOW TO CHANGE BELT WARNING Motor shaft can become hot during normal use.
  • Page 12: For All Models

    12 FOR ALL MODELS VACUUM POWER CONTROL EMPTYING THE DEBRIS PAIL WHEN TO EMPTY THE DEBRIS PAIL Fig. 10 Fig. 11 Reset . 10 . 11 CONTROL PANEL DIAGRAM A Broan VX3000C Fig. 11 Broan VX6000C and VX12000C AC0001...
  • Page 13 page 13 EMPTYING THE DEBRIS PAIL CLEANING THE SECONDARY FILTER ’ CONT CLEANING THE INTERNAL FILTER completely Fig. 12 CAUTION Operating the power unit without the secondary filter will void the warranty. . 12 A. F ILTER REMOVAL NOTE: B. F ILTER REINSTALLATION NIT DOOR ECONDARY...
  • Page 14: Troubleshooting Guide

    14 TROUBLESHOOTING GUIDE ROBLEMS OSSIBLE CAUSES OSSIBLE EMEDY Reset NOTE This applies only to Broan VX6000C and VX12000C.
  • Page 15: Service Parts

    15 SERVICE PARTS EPLACEMENT ARTS AND EPAIRS In order to ensure your ventilation unit remains in good working condition, you must use Broan-NuTone genuine replacement parts only. Broan-NuTone genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety.
  • Page 16: Warranty

    16 WARRANTY BROAN MODELS VX3000C, VX6000C AND VX12000C BROAN-NUTONE CANADA INC. During these time periods, IF YOU NEED ASSISTANCE OR SERVICE 1-888-882-7626...

This manual is also suitable for:

Vx6000cVx12000c

Table of Contents