Summary of Contents for Daikin REYAQ10P7Y1B

  • Page 1: Operation Manual

    OPERATION MANUAL VRVIII system air conditioner system air conditioner REYAQ10P7Y1B REYAQ12P7Y1B REYAQ14P7Y1B REYAQ16P7Y1B...
  • Page 2: Table Of Contents

    Some types of danger are represented by special symbols: 12. Important information regarding the refrigerant used ....10 Electric current. Thank you for purchasing this Daikin air conditioner. Danger of burning and scalding. The original instructions are written in English. All other languages are translations of the original instructions.
  • Page 3: Introduction

    Daikin. accessories could result in electric shock, short- circuit, leaks, fire or other damage to the equipment. Be sure to use only accessories made by Daikin which NTRODUCTION are specifically designed for use with the equipment and have them installed by a professional.
  • Page 4: What To Do Before Operation

    HAT TO DO BEFORE OPERATION CAUTION ■ It is not good for your health to expose your body to This operation manual is for the following systems with standard the air flow for a long time. control. Before initiating operation, contact your dealer for the ■...
  • Page 5: Operation Procedure

    PERATION PROCEDURE For systems with cool/heat changeover remote control switch ■ Operation procedure varies according to the combination of Overview of the changeover remote control switch outdoor unit and remote controller. Read "3. What to do before ONLY/AIR CONDITIONING operation" on page SELECTOR SWITCH ■...
  • Page 6: Program Dry Operation

    6.2. Program dry operation Explanation of heating operation ■ The function of this program is to decrease the humidity in your It may take longer to reach the set temperature for general heating room with minimal temperature decrease (minimal room operation than for cooling operation.
  • Page 7: Adjusting The Air Flow Direction

    6.3. Adjusting the air flow direction How to designate the master remote controller Press the operation mode selector button of the current master Refer to the operation manual of the remote controller. remote controller for 4 seconds. Movement of the air flow flap The display showing (change-over under centralized control) of all slave remote controllers connected to the same...
  • Page 8: Maintenance

    AINTENANCE OLLOWING SYMPTOMS ARE NOT AIR CONDITIONER TROUBLES CAUTION Symptom 1: The system does not operate Pay attention to the fan. ■ The air conditioner does not start immediately after the ON/OFF It is dangerous to inspect the unit while the fan is running. button on the remote controller is pressed.
  • Page 9: Troubleshooting

    Symptom 6.2: Indoor unit, outdoor unit Symptom 14: The inside of an outdoor unit is warm even when the unit ■ has stopped When the system is changed over to heating operation after ■ This is because the crankcase heater is warming the defrost operation compressor so that the compressor can start smoothly.
  • Page 10: After-Sales Service And Warranty

    11. A If the system does not properly operate except for the above FTER SALES SERVICE AND WARRANTY mentioned cases and none of the above mentioned malfunctions is evident, investigate the system according to the following procedures. Warranty period ■ If the system does not operate at all This product includes a warranty card that was filled in by the dealer at the time of installation.
  • Page 11: Shortening Of "Maintenance Cycle" And "Replacement Cycle" Needs To Be Considered In Following Situations

    12. I MPORTANT INFORMATION REGARDING THE NOTICE REFRIGERANT USED Table 1 indicates main components. Refer to your maintenance and inspection contract for This product contains fluorinated greenhouse gases covered by the more details. Kyoto Protocol. Table 1 indicates recommended intervals Refrigerant type: R410A maintenance cycles.
  • Page 12 4PW62583-1 11.2010...