SECTION 2: CIRCUIT
220V Operation
Serious personal injury could occur
if you connect the machine to the
power source before you have com-
pleted the set up process. DO NOT
connect the machine to the power
source until instructed to do so.
Amperage Draw
The 3 HP motor on the Model G0471 will
draw the following amps:
G0471 Motor Draw ......................18 Amps
Circuit Requirements
Only connect your machine to a cir-
cuit that meets the requirements below.
Always check to see if the wires and
circuit breaker in your circuit are capable
of handling the amperage draw from your
machine, as well as any other machines
that could be operating on the same cir-
cuit. If you are unsure, consult a qualified
electrician.
Minimum Circuit Requirement ..... 20 Amp
6
-
-
REQUIREMENTS
Plug/Receptacle Type
Plug Type ............. NEMA 6-20 (Figure 1)
Figure 1. Typical NEMA 6-20 plug and
receptacle.
Model G0471 3 HP Air Compressor