Haier DW-150W200 Operation Manual page 17

Super low temperature (slt) freezer
Table of Contents

Advertisement

Solutions: If the problem lies in control board, replace it; if lies in compressor itself, replace it or its
accessories.
Unstable temperature
Internal temperature does not reduce, but rises, e.g. rises to -80 ℃ from -140 ℃ .
Cause 1: Dirty condenser or clogged air vent
Solution: Clean the condenser
Cause 2: Slowdown of fan speed
Solution: Replace the fan
Cause 3: The freezer is extremely close to a wall
Solution: Move it far away from the wall for good ventilation
Cause 4: The freezer is placed in a closed narrow space
Solution: Install an air-conditioning system and improve ventilation condition
Cause 5: The freezer is not left still for a sufficient time and is energized before its system reaches
stable state, resulting in the problem of "oil beating" taken place in the compressor.
Solution: Turn off the freezer, leave it still over 24 hours, and then turn it on, gradually reduce the
temperature setting from -126 ℃ by following corresponding operating instructions.
Cause 6: The samples loaded at a time are over 1/5 of the freezer's effective capacity, or the
samples loaded are too hot (20 ℃ higher than the temperature setting, e.g. the samples temperature
is -106 ℃ or above and the temperature setting is -126 )
increases, so the compressor works for a prolonged time, and thus causes the temperature rise of
compressor, steep reduction of refrigeration effect as well as imbalance between the cold energy
provided by the refrigeration system and the loss of cold energy for the entry of ambient air, finally
resulting in the rise of internal temperature.
In this case, it is the fault of user for he/she uses the freezer as a quick freezer. However, the
appliance is a SLT freezer for maintaining the low temperature of articles with only a little
refrigeration and requires all the articles to be cooled down to basically equal temperature before
being put into it. If the user fails to follow instructions described in this manual, the continuous
℃ . In this case, the load of freezer greatly