Charcoal filter
(JX81A)
To remove the
charcoal filter
To install the
charcoal filter

Optional kits

42
The charcoal filter cannot be cleaned.
It must be replaced. Order Part No.
WB2X9883 from your GE supplier.
If the model is not vented to the
outside, the air will be recirculated
through a disposable charcoal filter
that helps remove smoke and odors.
To remove the charcoal filter, first
disconnect power at the main fuse.
Remove the top grille by removing
the 2 screws that hold it in place.
You may need to open the cabinet doors to
remove the screws.
Slide the filter towards the front of
the oven and remove it.
To install a new filter, remove plastic
and other outer wrapping from the
new filter.
Insert the filter into the top opening
of the oven as shown maneuvering it
behind the plastic grille until it fits
squarely into place.
It will rest at an angle behind the
plastic grille on two side support tabs
and in front of the right rear tab.
Replace the grille and 2 screws.
Reconnect power at the main fuse.
Available at extra cost from your GE supplier.
Filler Panel Kits
JX40CT—Bisque
JX40WH—White
JX41—Black
When replacing a 36 range hood,
filler panel kits fill in the additional
width to provide a custom built-in
appearance.
For installation between cabinets
only; not for end-of-cabinet
installation. Each kit contains
two 3 wide filler panels.
Care and Cleaning
www.geadvantium.com
The charcoal filter should be
replaced when it is noticeably dirty
or discolored (usually after 6 to
12 months, depending on usage).
Remove 2 grille screws to
remove the grille.
Filter Kits
JX81A—Recirculating Charcoal Filter
Kit
Filter kits are used when the oven
cannot be vented to the outside.
Decorative Panel Kit
JX22SS—Stainless Steel
When replacing a Hi/Low range, the
decorative panel kit fills in the area
between the oven and the range left
by the Hi/Low model.