Upright Filter Removal; Induced Draft And Circulator Blower Motors; Flame Sensor (Qualified Servicer Only ); Igniter (Qualified Servicer Only ) - Goodman GDS8 Installation And Operating Instructions Manual

Gas fired warm air furnace single stage
Table of Contents

Advertisement

U
F
R
PRIGHT
ILTER
EMOVAL
To remove filters from an external filter rack in an upright upflow
installation, follow the directions provided with external filter rack
kit.
Clean, wash and dry a permanent filter. When using a metal filter,
both sides should be sprayed with a dust adhesive as
recommended on adhesive container. Spray adhesives for use
with permanent metal filters can be found at some hardware
stores. BE SURE AIRFLOW DIRECTION ARROW POINTS
TOWARDS THE BLOWER.
Inspect filter. If your dirty filter is the disposable type, replace dirty
with the same type and size filter. If your dirty filter is a permanent
metal filter, clean as follows:
• Wash, rinse, and dry the permanent filters. Both sides
should then be sprayed with a filter adhesive as is
recommended on the adhesive container. Many hardware
stores stock spray adhesives for use with permanent filters.
• If badly torn or uncleanable, these filters must be replaced
by equal size permanent, high velocity filters. Throwaway
filters must not be used as replacement for permanent
filters. Under normal use, permanent filters should last for
several years.
I
D
C
NDUCED
RAFT AND
IRCULATOR
The bearings in the induced draft blower and circulator blower
motors are permanently lubricated by the manufacturer. No further
lubrication is required. Check motor windings for accumulation of
dust which may cause overheating. Clean as necessary.
F
S
(Q
LAME
ENSOR
UALIFIED
Under some conditions, the fuel or air supply can create a nearly
invisible coating on the flame sensor. This coating acts as an
insulator causing a drop in the flame sense signal. If the flame
sense signal drops too low the furnace will not sense flame and
will lock out. The flame sensor should be carefully cleaned by a
qualified servicer using emery cloth or steel wool. Following
cleaning, the flame sense signal should be as indicated in the
Specifications Sheet.
I
(Q
S
GNITER
UALIFIED
ERVICER
If the igniter and the surrounding air are at about 70°F and the
igniter wires are not connected to any other electrical components,
the resistance of the igniter should not exceed 200 ohms. If it does,
the igniter should be replaced.
B
URNERS
T
O PREVENT PERSONAL INJURY OR DEATH, DO NOT REMOVE ANY INTERNAL
COMPARTMENT COVERS OR ATTEMPT ANY ADJUSTMENT.
COMPONENTS ARE CONTAINED IN BOTH COMPARTMENTS.
QUALIFIED SERVICE AGENT AT ONCE IF AN ABNORMAL FLAME APPEARANCE
SHOULD DEVELOP.
Periodically during the heating season make a visual check of the
burner flames. Turn the furnace on at the thermostat. Wait a few
minutes, since any dislodged dust will alter the normal flame
appearance. Flames should be stable, quiet, soft and blue with
slightly orange tips. They should not be yellow. They should
extend directly outward from the burner ports without curling
downward, floating or lifting off the ports.
IO-242C
B
M
LOWER
OTORS
S
O
)
ERVICER
NLY
O
)
NLY
WARNING
E
LECTRICAL
C
ONTACT A
C
(Q
S
LEANING
UALIFIED
ERVICER
1. Shut off electric power and gas supply to the furnace.
2. Remove screws securing manifold to burner bracket.
Slightly pull manifold out and away from burner bracket.
Burners will drop. Re-secure manifold to burner bracket.
3. Tilt burners to slotted side of burner bracket. Rotate burners
clockwise to remove.
4. Use bottle brush to clean burner insert and inside of burner.
5. Replace burner (opposite of removal). Ensure burners
are fully seated on burner bracket tabs and are properly
aligned.
6. Turn on electric power and gas supply to the furnace.
7. Check furnace for proper operation. Refer to "Operational
Checks" section to verify burner flame characteristics.
XVII. BEFORE LEAVING AN INSTALLATION
Cycle the furnace with the thermostat at least three times.
Verify cooling and fan only operation.
Review the Owner's Manual with the homeowner and
discuss proper furnace operation and maintenance.
Leave literature packet near furnace.
XVIII. REPAIR AND REPLACEMENT PARTS
When ordering any of the listed functional parts, be sure to
provide the furnace model, manufacturing, and serial
numbers with the order.
Although only functional parts are shown in the parts list,
all sheet metal parts, doors, etc. may be ordered by
description.
Parts are available from your Amana distributor.
Functional Parts List-
Single Stage Gas Valve
Natural Gas Orifice
Propane Gas Orifice
Burner
Hot Surface Igniter
Flame Sensor
Gas Manifold
Ignition Control
Blower Mounting Bracket
Pressure Switch
Pressure Switch Hose
Induced Draft Blower
Collector Box
28
O
)
NLY
Blower/Box Gasket
Rollout Limit Switch
Auxiliary Limit Switch
Heat Exchanger
Door Switch
Transformer
Blower Wheel
Blower Housing
Blower Cutoff
Blower Motor
Motor Mount Bracket
Capacitor
05/05