Installation; Mains Connection - Behringer XENYX 502 User Manual

Premium 12/10/8/5-input 2-bus mixer with xenyx mic preamp and british eq
Hide thumbs Also See for XENYX 502:
Table of Contents

Advertisement

9
XENYX 1202/1002/802/502 User Manual
2-TRACK OUTPUT
These connectors are wired in parallel with the MAIN OUT and carry the main
mix signal (unbalanced). Connect the 2-TRACK OUTPUT to the inputs of your
recording device. The output level is adjusted via the high-precision MAIN MIX
fader or rotary control (802).
2.3.4 Signal assignment
Fig. 2.12: Assignment switches of the main section
2-TR TO MIX
When the 2-TR TO MIX switch is depressed, the 2-track input is assigned to the
main mix providing an additional input for tape machines, MIDI instruments or
other signal sources that do not require any processing.
2-TR TO CTRL ROOM (502: 2-TR TO PHONES)
Press the 2-TR TO CTRL ROOM/PHONES switch if you want to monitor the
2-track input via the CTRL ROOM OUT. This provides an easy way to monitor
signals coming back from tape to ensure that they are recording correctly.
If you are recording a signal via the 2-TRACK OUTPUT and wish to listen
to this simultaneously via the 2-TRACK INPUT, do not use the 2-TR TO
MIX switch. Doing this would create a feedback loop, since the signal
would be routed, via the main mix, back to tape via the 2-TRACK
OUTPUT. To monitor the 2-TRACK INPUT, use the 2-TR TO CTRL ROOM
switch to assign the tape signal to the monitor(s) or headphones.
This will avoid the tape signal being routed to the 2-TRACK OUTPUT.
FX TO CTRL
If you want to monitor only the FX send signal in your headphones or monitor
speaker(s), press the FX TO CTRL switch. This mutes the main mix signal while
routing the FX SEND output to the monitor(s). The XENYX 802 and 502 do not
feature this switch.
2.3.5 Phantom power and LED displays
Fig. 2.13: Phantom power and control LEDs
+48 V
The red +48 V LED lights up when phantom power is on. The PHANTOM switch
activates the phantom power supply on the XLR connectors of all mono channels.
Please do not connect microphones to the mixer (or the stagebox/
wallbox) as long as the phantom power supply is switched on.
Connect the micro-phones before you switch on the power supply.
In addition, the monitor/PA loudspeakers should be muted before you
activate the phantom power supply. After switching on, wait approx.
one minute in order to allow system stabilization.
POWER
The blue POWER LED indicates that the console is powered on.
Level indicator
The high-precision 4-segment display accurately displays the relevant
signal level.
LEVEL SETTING: To correctly set the gains of the channels, first set the LEVEL
controls of the input channels to their center positions (0 dB). Then use the GAIN
controls to increase the input amplification until signal peaks show 0 dB on the
level meter.
When recording to digital recorders, the recorder's peak meter should not go into
overload. While analog recorders can be overloaded to some extent, creating only
a certain amount of distortion (which is common and often desirable),
digital recorders distort quickly when overloaded. In addition, digital distortion is
not only undesirable, but also renders your recording completely useless.
The peak meters of your XENYX display the level virtually independent
of frequency. A recording level of 0 dB is recommended for all
signal types.

3. Installation

3.1 Mains connection

AC POWER IN
Connect the power supply to the 3-pin mains connector on the rear of the
console. Use the AC adapter supplied to connect the console to the mains.
The adapter complies with all applicable safety standards.
Please use only the power supply unit provided with the console.
Never connect the XENYX to the power supply unit while the latter is
connected to the mains! First connect the console to the power supply
unit, then connect the power supply unit to the mains.
Please note that both the power supply unit and the mixing console
heat up considerably during operation. This is completely normal.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xenyx 1002Xenyx 802Xenyx 1202Xenyx 802Xenyx 1002

Table of Contents