METROLOGIC INSTRUMENTS, INC.
MS7120 Orbit
Presentation
®

Laser Scanner

Installation and User's Guide

Advertisement

Table of Contents
loading

Summary of Contents for Metrologic MS7120 Orbit

  • Page 1: Laser Scanner

    METROLOGIC INSTRUMENTS, INC. MS7120 Orbit Presentation ® Laser Scanner Installation and User’s Guide...
  • Page 2 Copyright © 2005 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976.
  • Page 3: Table Of Contents

    ABLE OF ONTENTS Introduction....................1 Scanner and Accessories................2 Operational Notes ..................3 Installation For RS232, OCIA and IBM 46XX Interfaces.........4 For Keyboard Wedge Interface .............5 For Stand Alone Keyboard Interface.............6 Notes for USB Interface ................7 Notes for MS7120-00 'Laser Emulation' ..........7 Scanner Parts....................8 Audible Indicators..................9 Visual Indicators ..................10 Failure Modes..................11...
  • Page 4 ABLE OF ONTENTS Installing the Optional Wall/Counter Mount ..........21 Troubleshooting Guide ................22 RS-232 Demonstration Program .............27 Applications and Protocols ..............28 Design Specifications ................29 Default Settings ..................31 Scanner and Cable Terminations............36 Limited Warranty ..................39 Notices ....................40 Patents ....................44 Index......................45...
  • Page 5: Introduction

    NTRODUCTION ® Orbit is an aggressive, omnidirectional laser bar code scanner. Lightweight and rugged, Orbit is small in size, but BIG in performance. Designed for applications where counter space is limited, Orbit is the ideal presentation scanner for retail, convenience, liquor and specialty stores.
  • Page 6: Scanner And Accessories

    CANNER AND CCESSORIES ASIC Part # Description ® MS7120 Orbit Presentation Laser Scanner ® 00-02407 MetroSelect Programming Guide 00-02408 MS7120 Installation and User’s Guide* Available on the Metrologic website - www.metrologic.com PTIONAL CCESSORIES Part # Description AC to DC Power Transformer- Regulated 5.2VDC @ 650 mA output. 45-45593 120V United States 45-45591...
  • Page 7: Operational Notes

    CANNER AND CCESSORIES PTIONAL CCESSORIES Part # Description Metrologic Voltage Converter Cable MVC** +12VDC to +5.2VDC or -12VDC to +5.2VDC MX009-2** MX009 USB Converter Cable ** Contact a Metrologic customer service representative for additional information on the MVC and MX009 cable series and the host connections available.
  • Page 8: For Rs232, Ocia And Ibm 46Xx Interfaces

    RS232, OCIA IBM 46XX I NSTALLATION FOR NTERFACES 1. Turn off the host system. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin jack on the MS7120. 3. Connect the 9 pin female end of the PowerLink cable to the host device.
  • Page 9: For Keyboard Wedge Interface

    NSTALLATION FOR EYBOARD EDGE NTERFACE 1. Turn off the PC/Host. 2. Connect the male 10-pin RJ45 end of the PowerLink cable to the jack on the MS7120. 3. Connect the L-shaped plug of the power supply into the power jack on the PowerLink cable.
  • Page 10: For Stand Alone Keyboard Interface

    NSTALLATION FOR TAND LONE EYBOARD NTERFACE 1. Turn off the host system. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin jack on the MS7120. 3. Connect the PowerLink cable to the keyboard port on the host system. 4.
  • Page 11: Notes For Usb Interface

    USB I NSTALLATION OTES FOR NTERFACE Metrologic’s MX009 USB cable is a device that converts serial RS232 formatted data to either USB Keyboard or USB Point-of Sale communication protocol. Please refer to the MX009 USB Converter Cable Programming Guide 00-02574A) supplied with your MX009 cable for detailed MLPN installation and programming guidelines.
  • Page 12: Scanner Parts

    CANNER ARTS Red LED On a successful read of a bar code, the red LED will turn ON. After communication to the host is complete, the red LED will turn OFF. Refer to Visual Indicators and Audible Indicators for additional information. Green LED During normal operation, the green LED is ON.
  • Page 13: Audible Indicators

    UDIBLE NDICATORS When the MS7120 scanner is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). ® To change the tone, refer to the MetroSelect Programming Guide ( MLPN 00-02407B) or the MetroSet2 help files.
  • Page 14: Visual Indicators

    ISUAL NDICATORS There is a red LED and a green LED on the head of the MS7120. When the scanner is on, the flashing or constant illumination of the LEDs indicates the status of the current scan and the scanner. No Red or Green LED The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer.
  • Page 15: Failure Modes

    AILURE ODES Flashing Green and One Razzberry Tone This indicates the scanner has experienced a laser subsystem failure. Return the unit for repair at an authorized service center. Flashing Red and Green and Two Razzberry Tones This indicates the scanner has experienced a motor failure.
  • Page 16: Labels

    ABELS Each scanner has three labels on the bottom of the unit. These labels contain information such as; the model number, date of manufacture, serial number, laser class and caution statements. The following illustrations show the location and content of the three labels. AINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code.
  • Page 17: Scan Volume Specifications

    OLUME PECIFICATIONS Specifications based on 100% UPC Bar Codes. Optimal Low Density (Default) 190mm 60mm 100mm Scan Area Optimal High Density 215mm 60mm 105mm Scan Area...
  • Page 18: Close

    OLUME PECIFICATIONS Specifications based on 100% UPC Bar Codes. Close 175mm 60mm 95mm Scan Area Normal 190mm 60mm 100mm Scan Area...
  • Page 19: Far

    OLUME PECIFICATIONS Specifications based on 100% UPC Bar Codes. 215mm 75mm 105mm 75mm Scan Area...
  • Page 20: Optimal Low Density (Default)

    EPTH OF IELD BY INIMUM LEMENT IDTH Optimal Low Density (Default) & Distance: Scanner Face & To Bar Code (mm) Width of Scan Field (mm) Minimum Bar Code Element Width mils...
  • Page 21: Optimal High Density

    EPTH OF IELD BY INIMUM LEMENT IDTH Optimal High Density & Distance: Scanner Face & To Bar Code (mm) Width of Scan Field (mm) Minimum Bar Code Element Width mils...
  • Page 22: Close

    EPTH OF IELD BY INIMUM LEMENT IDTH Close Distance: Scanner Face To Bar Code (mm) Width of Scan Field (mm) Minimum Bar Code Element Width mils...
  • Page 23: Normal

    EPTH OF IELD BY INIMUM LEMENT IDTH Normal Distance: & Scanner Face To Bar Code & (mm) Width of Scan Field (mm) Minimum Bar Code Element Width mils...
  • Page 24: Far

    EPTH OF IELD BY INIMUM LEMENT IDTH Distance: Scanner Face To Bar Code (mm) & Width of Scan Field (mm) Minimum Bar Code Element Width mils...
  • Page 25: Installing The Optional Wall/Counter Mount

    NSTALLING THE PTIONAL OUNTER OUNT Kit #45-45619 contains: Locking Plate 50-50302] ......Qty. 1 MLPN Base Cover 50-50301] ......Qty. 1 MLPN Wood Screw, #7 x 1.00” 18-18013] ......Qty. 3 MLPN Flathead Screw, M3 x 8 mm Fig. 1 18-18004] ......
  • Page 26: Troubleshooting Guide

    ROUBLESHOOTING UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms on page 39. All Interfaces MS7120 Series Troubleshooting Guide SYMPTOMS POSSIBLE CAUSE(S) SOLUTION No LEDs, beep No power is being Check transformer, outlet and or motor spin...
  • Page 27 ROUBLESHOOTING UIDE ONTINUED SYMPTOMS POSSIBLE CAUSE(S) SOLUTION The unit powers Beeper disabled. No Enable beeper. Select tone up, but does tone selected not scan and/or beep The unit powers Scanning a particular UPC/EAN, Code 39, interleaved up, but does symbology that is not 2 of 5, Code 93, Code 128 and enabled Codabar are enabled by default.
  • Page 28 ROUBLESHOOTING UIDE ONTINUED SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Scanner beeps The print quality of the Check print mode. The type of at some bar bar code is suspect printer could be the problem. codes and NOT Change print settings. For for others of the example change to econo mode same bar code or high speed...
  • Page 29 ROUBLESHOOTING UIDE ONTINUED Keyboard Wedge Only SYMPTOMS POSSIBLE CAUSE(S) SOLUTION The unit scans Configuration is not Make sure the scanner is the bar code correct configured for the appropriate but there is no mode. Check internal jumper data The unit scans Configuration is not Make sure that the proper PC but the data is...
  • Page 30 ROUBLESHOOTING UIDE CONTINUED RS-232 Only SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Power-up OK Com port at the host is Check to make sure that the and scans OK not working or baud rate and parity of the but does not configured properly scanner and the communication communicate port match and the program is...
  • Page 31: Rs-232 Demonstration Program

    RS-232 D EMONSTRATION ROGRAM If an RS-232 scanner is not communicating with your IBM compatible PC, key in the following BASIC program to test that the communication port and scanner are working. This program is for demonstration purposes only. It is only intended to prove that cabling is correct, the com port is working, and the scanner is working.
  • Page 32: Applications And Protocols

    PPLICATIONS AND ROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. ERSION CANNER OMMUNICATION ROTOCOL DENTIFIER Laser Emulation 7120 RS-232 Transmit/Receive OCIA and RS-232 Transmit/Receive 7120 (Full RS232 Configurable) 7120 IBM 46XX and Full RS-232C 7120 Full RS-232C/Light Pen Emulation Keyboard Wedge, Stand-Alone Keyboard and RS-...
  • Page 33: Design Specifications

    ESIGN PECIFICATIONS MS7120 S PECIFICATIONS PERATIONAL Light Source: VLD 640-660 nm Depth of Field: 0 mm to 216 mm (0" to 8.5") for 0.33 mm (13 mil) bar codes Scan Speed: 1067 scans/second Scan Pattern: 5 fields of 4 parallel lines (omnidirectional) Scan Lines: Min Bar Width: 0.13 mm (5.2 mil)
  • Page 34 ESIGN PECIFICATIONS MS7120 S PECIFICATIONS LECTRICAL Input Voltage: 5.2VDC ± 0.25V Power: 1.0 W typical Operating Current: 200 mA typical, 250 mA typical for IBM models DC Transformers: Class II; 5.2VDC@ 650 mA Laser Class: CDRH: Class IIa; EN 60825-1:1994/A11:1996 Class 1 EMC: FCC, ICES-003 &...
  • Page 35: Default Settings

    EFAULT ETTINGS Many functions of the scanner can be "programmed" - that is, enabled or disabled. The scanner is shipped from the factory programmed to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages. If an asterisk is not in the default column then the default setting is Off or Disabled.
  • Page 36 EFAULT ETTINGS Light Laser Parameter Default OCIA RS-232* 46XX Emulation ü DTS/NIXDORF ü NCR F ü NCR S ü Poll Light Pen Source ü ü ü ü ü ü Beeper Tone Normal ü ü ü ü ü ü Before Beep/Transmit Sequence Transmit ü...
  • Page 37 EFAULT ETTINGS Light Laser Parameter Default OCIA RS-232* 46XX Emulation ü ü ü ü Convert EAN-8 to EAN-13 ü ü ü ü ü ü Transmit UPC-A Number System ü ü ü ü ü ü Transmit UPC-A Manufacturer ID# ü ü ü...
  • Page 38 EFAULT ETTINGS Light Laser Parameter Default OCIA RS-232* 46XX Emulation ü ü Carriage Return ü ü Line Feed - disabled by default in KBW ü ü Tab Prefix ü ü Tab Suffix ü "DE" Disable Command ü "FL" Laser Enable Command ü...
  • Page 39 EFAULT ETTINGS Light Laser Parameter Default OCIA RS-232* 46XX Emulation ü ü ü ü as code Coupon Code 128 code ü ü ü ü ü ü Programmable Code 7 avail. Lengths ü Programmable Prefix Characters avail. ü Suffix Characters Prefixes for individual Code Types ü...
  • Page 40: Scanner And Cable Terminations

    CANNER AND ABLE ERMINATIONS Scanner Pinout Connections The MS7120 scanner interfaces terminate to a 10-pin modular jack. The serial # label indicates the interface enabled when the scanner is shipped from the factory. Some units have internal jumpers that can be moved to enable a different electrical interface.
  • Page 41 CANNER AND ABLE ERMINATIONS MS7120-11 IBM 46XX/RS-232 Function Ground RS-232 Transmit Output RS-232 Receive Input RTS Output CTS Input DTR Input IBM 46XX transmit IBM 46XX Receive +5VDC Shield Ground Options listed are program/cable selections Cable Connector configurations PowerLink Cable 54-54xxx* or 53-53xxx* MLPN Function...
  • Page 42 CANNER AND ABLE ERMINATIONS Cable Connector Configuration The PowerLink cable is terminated with a 5-pin DIN female connector on one end, and a 6-pin mini DIN male on the other. PowerLink Cable 5-Pin DIN, Female 6-Pin DIN, Male Metrologic will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other.
  • Page 43: Limited Warranty

    IMITED ARRANTY © The MS7120 Orbit scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The MS7120 scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS7120 scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S.
  • Page 44: Notices

    OTICES Notices This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
  • Page 45 OTICES Achtung Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder Verfahren kann eine gefährliche Laserstrahlung hervorrufen. Der Kunde sollte unter keinen Umständen versuchen, den Laser-Scanner selbst zu warten. Sehen Sie niemals in den Laserstrahl, selbst wenn Sie glauben, daß der Scanner nicht aktiv ist.
  • Page 46 OTICES Die nachfolgende Mitteilung gilt nur für Modell Nr. MS7120-11 Zur Klassifizierung gemäß Klasse B nach FCC Teil 15, ICES-003 und EN55022, befestigen Sie den vorliegenden Ferritkern an dem mitgelieferte PowerLink Kabel Ihres MS7120-11 Barcode Scanners. Ferritkern Installation: Entfernen Sie den vorliegenden Ferritkern aus der Schutzhülle.
  • Page 47 OTICES Nota (exclusivamente para los modelos de la serie MS7120-11) De acuerdo con las normativas FCC apartado 15, ICES-003 y EN55022 para la Clase B, el obturador de ferrita del PowerLink que se suministra con el modelo de lector de códigos de barras MS7120-11. Instalación del obturador de ferrita Quitar el envoltorio protector del obturador de ferrita...
  • Page 48: Patents

    ATENTS For patent information, please refer to www.honeywellaidc.com/patents.
  • Page 49: Index

    NDEX accessories......2, 3 failure indicator ......9 adapter....... 2, 3, 5, 38 failure modes ..... 9, 11 application......27 function ..22, 35, 36, 37, 38 audible ........9 authorized service center..11 autodiscriminates....29 green LED ......10 ground .......
  • Page 50 NDEX normal depth of field ....35 scan lines....... 29 notices ....40, 41, 42, 43 scan pattern....... 8, 29 scan speed ......29 scanner installation..4, 5, 6 SELV ....... 4, 5, 6 OCIA ....1-4, 28, 29, 31-36 shock ........30 omnidirectional....
  • Page 52 October 2005 Printed in USA 0 0 - 0 2 4 0 8 D...